Improved acetabular pressurization gives better cement penetration - In vivo measurements during total hip arthroplasty

Flivik, Gunnar LU ; Wulff, K ; Sanfridsson, J and Ryd, L (2004) In Journal of Arthroplasty 19(7). p.911-918
Abstract
During total hip arthroplasty, the intraoperative cementation pressure was measured inside one of the acetabular anchorage holes. Patients were randomized to pressurization of cement with either a conventional pressurizer or a sequential method including individual pressurization of each anchorage hole. The pressure was correlated to the cement penetration measured on digital radiographs. The early peak pressures were higher for the sequential method, resulting in a significantly better penetration of 2.8 mm compared with 0.7 mm with the conventional pressurizer. We found a strong correlation between early peak cementation pressures and cement penetration into the cancellous bone of the anchoring holes, indicating a cause-effect... (More)
During total hip arthroplasty, the intraoperative cementation pressure was measured inside one of the acetabular anchorage holes. Patients were randomized to pressurization of cement with either a conventional pressurizer or a sequential method including individual pressurization of each anchorage hole. The pressure was correlated to the cement penetration measured on digital radiographs. The early peak pressures were higher for the sequential method, resulting in a significantly better penetration of 2.8 mm compared with 0.7 mm with the conventional pressurizer. We found a strong correlation between early peak cementation pressures and cement penetration into the cancellous bone of the anchoring holes, indicating a cause-effect relationship at this early stage. The highest peak pressures were achieved during the later CLIP insertion, but these pressures did not correlate with the cement penetration. We conclude that conventional methods for cement pressurization in the acetabulum may not be optimal. (C) 2004 Elsevier Inc. All rights reserved. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
cement pressurization, total hip arthroplasty, acetabulum, cement, penetration
in
Journal of Arthroplasty
volume
19
issue
7
pages
911 - 918
publisher
Elsevier
external identifiers
  • wos:000224736900016
  • pmid:15483809
  • scopus:4644249764
ISSN
0883-5403
DOI
10.1016/j.arth.2004.06.027
language
English
LU publication?
yes
id
746f43ea-1600-4195-a4fa-cacf2eb71570 (old id 262405)
date added to LUP
2016-04-01 12:36:40
date last changed
2022-03-13 20:16:30
@article{746f43ea-1600-4195-a4fa-cacf2eb71570,
  abstract     = {{During total hip arthroplasty, the intraoperative cementation pressure was measured inside one of the acetabular anchorage holes. Patients were randomized to pressurization of cement with either a conventional pressurizer or a sequential method including individual pressurization of each anchorage hole. The pressure was correlated to the cement penetration measured on digital radiographs. The early peak pressures were higher for the sequential method, resulting in a significantly better penetration of 2.8 mm compared with 0.7 mm with the conventional pressurizer. We found a strong correlation between early peak cementation pressures and cement penetration into the cancellous bone of the anchoring holes, indicating a cause-effect relationship at this early stage. The highest peak pressures were achieved during the later CLIP insertion, but these pressures did not correlate with the cement penetration. We conclude that conventional methods for cement pressurization in the acetabulum may not be optimal. (C) 2004 Elsevier Inc. All rights reserved.}},
  author       = {{Flivik, Gunnar and Wulff, K and Sanfridsson, J and Ryd, L}},
  issn         = {{0883-5403}},
  keywords     = {{cement pressurization; total hip arthroplasty; acetabulum; cement; penetration}},
  language     = {{eng}},
  number       = {{7}},
  pages        = {{911--918}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Arthroplasty}},
  title        = {{Improved acetabular pressurization gives better cement penetration - In vivo measurements during total hip arthroplasty}},
  url          = {{http://dx.doi.org/10.1016/j.arth.2004.06.027}},
  doi          = {{10.1016/j.arth.2004.06.027}},
  volume       = {{19}},
  year         = {{2004}},
}