Dual-pump dual-broadband coherent anti-Stokes Raman scattering in reacting flows
(2004) In Optics Letters 29(16). p.1843-1845- Abstract
- A dual-pump, dual-broadband coherent anti-Stokes Raman scattering system for simultaneous measurements of temperature and concentrations of N-2, O-2, and CO2 in reacting flows is demonstrated. In this system pure rotational transitions of N-2-O-2 and rovibrational transitions of N-2-CO2 are probed simultaneously with two narrowband pump beams, a broadband pump beam, and a broadband Stokes beam. The main advantage of this technique is that it permits accurate temperature measurements at both low and high temperatures as well as concentration measurements of three molecules. (C) 2004 Optical Society of America.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/271089
- author
- Roy, S ; Meyer, TR ; Lucht, RP ; Afzelius, Mikael LU ; Bengtsson, Per-Erik LU and Gord, JR
- organization
- publishing date
- 2004
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Optics Letters
- volume
- 29
- issue
- 16
- pages
- 1843 - 1845
- publisher
- Optical Society of America
- external identifiers
-
- wos:000223074600003
- pmid:15357334
- scopus:4043120975
- ISSN
- 0146-9592
- language
- English
- LU publication?
- yes
- id
- d71cd391-34e8-467b-89e8-2c9bec67a929 (old id 271089)
- alternative location
- http://www.opticsinfobase.org/abstract.cfm?URI=ol-29-16-1843
- date added to LUP
- 2016-04-01 16:24:38
- date last changed
- 2022-01-28 19:28:42
@article{d71cd391-34e8-467b-89e8-2c9bec67a929, abstract = {{A dual-pump, dual-broadband coherent anti-Stokes Raman scattering system for simultaneous measurements of temperature and concentrations of N-2, O-2, and CO2 in reacting flows is demonstrated. In this system pure rotational transitions of N-2-O-2 and rovibrational transitions of N-2-CO2 are probed simultaneously with two narrowband pump beams, a broadband pump beam, and a broadband Stokes beam. The main advantage of this technique is that it permits accurate temperature measurements at both low and high temperatures as well as concentration measurements of three molecules. (C) 2004 Optical Society of America.}}, author = {{Roy, S and Meyer, TR and Lucht, RP and Afzelius, Mikael and Bengtsson, Per-Erik and Gord, JR}}, issn = {{0146-9592}}, language = {{eng}}, number = {{16}}, pages = {{1843--1845}}, publisher = {{Optical Society of America}}, series = {{Optics Letters}}, title = {{Dual-pump dual-broadband coherent anti-Stokes Raman scattering in reacting flows}}, url = {{http://www.opticsinfobase.org/abstract.cfm?URI=ol-29-16-1843}}, volume = {{29}}, year = {{2004}}, }