Characterization of a new large area HPGe X-ray detector for low beam current application
(2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.494-498- Abstract
- In the new sub-micron beamline at the Lund Nuclear Microprobe facility a special large area HPGe X-ray detector has been installed. It consists of eight 100-mm(2)-size detector elements arranged in an annular formation around the beam entrance hole. Different parameters like FWHM, FWTM, peak-to-background ratio and peak-to-valley ratio for each individual detector element as well as their sum spectra have been investigated. The data handling, i.e. how eight parallel signals are individually stored and summed together, has been discussed. The possibility to use the detector for simultaneous measurement of high and low energy photons, i.e. PINE combined with PIGE has been demonstrated. (C) 2004 Elsevier B.V. All rights reserved.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/275141
- author
- Shariff, Asad LU ; Kristiansson, Per LU ; Auzelyte, Vaida LU ; Elfman, Mikael LU ; Malmqvist, Klas LU ; Nilsson, Christer LU ; Pallon, Jan LU and Wegdén, Marie LU
- organization
- publishing date
- 2004
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- PIXE, annular detector, PIGE, HPGe detector
- in
- Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms
- volume
- 219-20
- pages
- 494 - 498
- publisher
- Elsevier
- external identifiers
-
- wos:000221895800094
- scopus:2342446523
- ISSN
- 0168-583X
- DOI
- 10.1016/j.nimb.2004.01.109
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007)
- id
- 690b0ff1-e282-48b3-a041-5904b7ed3e70 (old id 275141)
- date added to LUP
- 2016-04-01 16:21:48
- date last changed
- 2022-01-28 19:12:13
@article{690b0ff1-e282-48b3-a041-5904b7ed3e70, abstract = {{In the new sub-micron beamline at the Lund Nuclear Microprobe facility a special large area HPGe X-ray detector has been installed. It consists of eight 100-mm(2)-size detector elements arranged in an annular formation around the beam entrance hole. Different parameters like FWHM, FWTM, peak-to-background ratio and peak-to-valley ratio for each individual detector element as well as their sum spectra have been investigated. The data handling, i.e. how eight parallel signals are individually stored and summed together, has been discussed. The possibility to use the detector for simultaneous measurement of high and low energy photons, i.e. PINE combined with PIGE has been demonstrated. (C) 2004 Elsevier B.V. All rights reserved.}}, author = {{Shariff, Asad and Kristiansson, Per and Auzelyte, Vaida and Elfman, Mikael and Malmqvist, Klas and Nilsson, Christer and Pallon, Jan and Wegdén, Marie}}, issn = {{0168-583X}}, keywords = {{PIXE; annular detector; PIGE; HPGe detector}}, language = {{eng}}, pages = {{494--498}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms}}, title = {{Characterization of a new large area HPGe X-ray detector for low beam current application}}, url = {{http://dx.doi.org/10.1016/j.nimb.2004.01.109}}, doi = {{10.1016/j.nimb.2004.01.109}}, volume = {{219-20}}, year = {{2004}}, }