Design of a portable large spectral range grazing incidence instrument
(1986) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 246(1-3). p.242-245- Abstract
A design of a small size grazing incidence instrument is presented, which offers large spectral range and high resolution without sacrificing luminosity. The instrument is particularly suited for use at synchrotron radiation sources since it can be conveniently attached to existing experiment chambers. The basic idea of the design is the use of fixed mounted gratings of diffent radii and groove densities and a big two-dimensional position sensitive detector mounted on a x-y angle table. The design is discussed in some detail and performance is presented.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/30263d32-2c9d-486e-9913-b8f30b8f67be
- author
- Nordgren, J. and Nyholm, R.
- publishing date
- 1986-05-15
- type
- Contribution to journal
- publication status
- published
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 246
- issue
- 1-3
- pages
- 4 pages
- publisher
- Elsevier
- external identifiers
-
- scopus:0022063430
- ISSN
- 0168-9002
- DOI
- 10.1016/0168-9002(86)90081-1
- language
- English
- LU publication?
- no
- id
- 30263d32-2c9d-486e-9913-b8f30b8f67be
- date added to LUP
- 2016-08-19 11:14:14
- date last changed
- 2021-09-26 03:36:58
@article{30263d32-2c9d-486e-9913-b8f30b8f67be, abstract = {{<p>A design of a small size grazing incidence instrument is presented, which offers large spectral range and high resolution without sacrificing luminosity. The instrument is particularly suited for use at synchrotron radiation sources since it can be conveniently attached to existing experiment chambers. The basic idea of the design is the use of fixed mounted gratings of diffent radii and groove densities and a big two-dimensional position sensitive detector mounted on a x-y angle table. The design is discussed in some detail and performance is presented.</p>}}, author = {{Nordgren, J. and Nyholm, R.}}, issn = {{0168-9002}}, language = {{eng}}, month = {{05}}, number = {{1-3}}, pages = {{242--245}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{Design of a portable large spectral range grazing incidence instrument}}, url = {{http://dx.doi.org/10.1016/0168-9002(86)90081-1}}, doi = {{10.1016/0168-9002(86)90081-1}}, volume = {{246}}, year = {{1986}}, }