Cantilever-based sensor with integrated optical read-out using single mode waveguides
(2007) 11th International Conference on Miniaturised Systems for Chemistry and Life Sciences (µTAS 2007) p.497-499- Abstract
- This work presents the design, fabrication and mechanical characterisation of an integrated optical read-out scheme for cantilever-based biosensors. A cantilever can be used as a biosensor by monitoring its bending caused by the surface stress generated due to chemical reactions occurring on its surface. Here, we present a novel integrated optical read-out scheme based on single-mode waveguides that enables the fabrication of a compact system. The complete system is fabricated in the polymer SU-8. This manuscript shows the principle of operation and the design well as the fabrication of the system and characterisation of the read-out method.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/3164933
- author
- Tenje, Maria LU ; Zauner, D.A. ; Calleja, M. ; Hübner, J. and Boisen, Anja
- publishing date
- 2007
- type
- Contribution to conference
- publication status
- published
- subject
- pages
- 497 - 499
- conference name
- 11th International Conference on Miniaturised Systems for Chemistry and Life Sciences (µTAS 2007)
- conference location
- Paris, France
- conference dates
- 2007-10-07 - 2007-10-11
- external identifiers
-
- scopus:84925698137
- language
- English
- LU publication?
- no
- id
- fdd5f166-5ab6-46cf-a3f9-2d405a684de2 (old id 3164933)
- date added to LUP
- 2016-04-04 14:08:05
- date last changed
- 2022-03-23 21:11:51
@misc{fdd5f166-5ab6-46cf-a3f9-2d405a684de2, abstract = {{This work presents the design, fabrication and mechanical characterisation of an integrated optical read-out scheme for cantilever-based biosensors. A cantilever can be used as a biosensor by monitoring its bending caused by the surface stress generated due to chemical reactions occurring on its surface. Here, we present a novel integrated optical read-out scheme based on single-mode waveguides that enables the fabrication of a compact system. The complete system is fabricated in the polymer SU-8. This manuscript shows the principle of operation and the design well as the fabrication of the system and characterisation of the read-out method.}}, author = {{Tenje, Maria and Zauner, D.A. and Calleja, M. and Hübner, J. and Boisen, Anja}}, language = {{eng}}, pages = {{497--499}}, title = {{Cantilever-based sensor with integrated optical read-out using single mode waveguides}}, year = {{2007}}, }