Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Improvement in time-domain induced polarization data quality with multi-electrode systems by separating current and potential cables

Dahlin, Torleif LU and Leroux, Virginie LU (2012) In Near Surface Geophysics 10(6). p.545-565
Abstract
Measuring induced polarization in the time domain with relatively compact multi-channel multi-electrode systems is attractive because of the simplicity of the procedure and thus its efficiency in the field. However the use of this technique is sometimes discouraged by the bad quality of the measurements in cases of high electrode contact resistances that can render data interpretation infeasible or at least unreliable. It is proposed that capacitive coupling in the multi-core electrode cables has a significant role in creating this problem. In such cases separation of current and potential circuits by using separate multi-conductor cable spreads can yield significant improvement in data quality. The procedure is relatively simple and can... (More)
Measuring induced polarization in the time domain with relatively compact multi-channel multi-electrode systems is attractive because of the simplicity of the procedure and thus its efficiency in the field. However the use of this technique is sometimes discouraged by the bad quality of the measurements in cases of high electrode contact resistances that can render data interpretation infeasible or at least unreliable. It is proposed that capacitive coupling in the multi-core electrode cables has a significant role in creating this problem. In such cases separation of current and potential circuits by using separate multi-conductor cable spreads can yield significant improvement in data quality. The procedure is relatively simple and can be implemented with common resistivity and time-domain IP equipment. We show here three field examples from Southern Sweden, all measured as 2D electrical imaging sections. The first one is an example where the use of a single cable spread is sufficient thanks to moderate electrode contact resistance and high signal levels. The following two examples are from sites where induced polarization measurements could not yield consistent results using only a single multi-conductor cable spread. Useful results were subsequently obtained by using separate cable spreads. The first example is a 280 m long line measured over an old covered municipal waste deposit where the waste body stands out as a zone of high chargeability. The second example is a 120 m line measured on a sandy glaciofluvial structure that is host to an aquifer of regional importance. The improvement led to discrimination between materials of different grain sizes, with potential bearing for understanding the aquifer. The third example is a 300-400 m line measured across an esker lying on clay till. The improvement led to a clear visualization of the esker and to the identification of a possible fault in the underlying gneissic bedrock. In all cases pseudosections and examples of chargeability decay curves are shown and discussed as tools for assessing data quality. Inversion results are shown together with background geological information and it is concluded that they are in good agreement. (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Near Surface Geophysics
volume
10
issue
6
pages
545 - 565
publisher
EAGE
external identifiers
  • wos:000312975800009
  • scopus:84871298668
ISSN
1873-0604
DOI
10.3997/1873-0604.2012028
language
English
LU publication?
yes
id
10369dad-f55c-4933-aabc-7ade7da0ef4c (old id 3492305)
date added to LUP
2016-04-01 09:53:32
date last changed
2022-04-27 08:29:55
@article{10369dad-f55c-4933-aabc-7ade7da0ef4c,
  abstract     = {{Measuring induced polarization in the time domain with relatively compact multi-channel multi-electrode systems is attractive because of the simplicity of the procedure and thus its efficiency in the field. However the use of this technique is sometimes discouraged by the bad quality of the measurements in cases of high electrode contact resistances that can render data interpretation infeasible or at least unreliable. It is proposed that capacitive coupling in the multi-core electrode cables has a significant role in creating this problem. In such cases separation of current and potential circuits by using separate multi-conductor cable spreads can yield significant improvement in data quality. The procedure is relatively simple and can be implemented with common resistivity and time-domain IP equipment. We show here three field examples from Southern Sweden, all measured as 2D electrical imaging sections. The first one is an example where the use of a single cable spread is sufficient thanks to moderate electrode contact resistance and high signal levels. The following two examples are from sites where induced polarization measurements could not yield consistent results using only a single multi-conductor cable spread. Useful results were subsequently obtained by using separate cable spreads. The first example is a 280 m long line measured over an old covered municipal waste deposit where the waste body stands out as a zone of high chargeability. The second example is a 120 m line measured on a sandy glaciofluvial structure that is host to an aquifer of regional importance. The improvement led to discrimination between materials of different grain sizes, with potential bearing for understanding the aquifer. The third example is a 300-400 m line measured across an esker lying on clay till. The improvement led to a clear visualization of the esker and to the identification of a possible fault in the underlying gneissic bedrock. In all cases pseudosections and examples of chargeability decay curves are shown and discussed as tools for assessing data quality. Inversion results are shown together with background geological information and it is concluded that they are in good agreement.}},
  author       = {{Dahlin, Torleif and Leroux, Virginie}},
  issn         = {{1873-0604}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{545--565}},
  publisher    = {{EAGE}},
  series       = {{Near Surface Geophysics}},
  title        = {{Improvement in time-domain induced polarization data quality with multi-electrode systems by separating current and potential cables}},
  url          = {{https://lup.lub.lu.se/search/files/1362320/4934453.pdf}},
  doi          = {{10.3997/1873-0604.2012028}},
  volume       = {{10}},
  year         = {{2012}},
}