Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Free oscillation rheometry monitoring of haemodilution and hypothermia and correction with fibrinogen and factor XIII concentrates.

Winstedt, Dag LU ; Tynngård, Nahreen ; Olanders, Knut LU and Schött, Ulf LU (2013) In Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine 21.
Abstract
Haemodilution and hypothermia induce coagulopathy separately, but their combined effect on coagulation has not been widely studied. Fibrinogen concentrate can correct dilutional coagulopathy and has an additional effect when combined with factor XIII concentrate. However, their effect on dilutional coagulopathy concomitant with hypothermia has not been studied previously. Free oscillation rheometry - FOR (Reorox®) - is a novel viscoelastic haemostatic assay that has not been studied in this context before.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
concentrate, Coagulation factor, Free oscillation rheometry, Thrombelastography, Fibrinogen, Factor XIII, Haemodilution, Hypothermia, Coagulopathy, Hydroxyethyl starch, Ringer's acetate solution
in
Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
volume
21
article number
20
publisher
BioMed Central (BMC)
external identifiers
  • pmid:23517637
  • wos:000317330200001
  • scopus:84875178512
  • pmid:23517637
ISSN
1757-7241
DOI
10.1186/1757-7241-21-20
project
Koagulation vid kirurgi och kritisk sjukdom
language
English
LU publication?
yes
id
fd86e506-a676-49f6-9f49-af306e85477f (old id 3634252)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/23517637?dopt=Abstract
date added to LUP
2016-04-01 13:15:04
date last changed
2022-03-29 06:24:25
@article{fd86e506-a676-49f6-9f49-af306e85477f,
  abstract     = {{Haemodilution and hypothermia induce coagulopathy separately, but their combined effect on coagulation has not been widely studied. Fibrinogen concentrate can correct dilutional coagulopathy and has an additional effect when combined with factor XIII concentrate. However, their effect on dilutional coagulopathy concomitant with hypothermia has not been studied previously. Free oscillation rheometry - FOR (Reorox®) - is a novel viscoelastic haemostatic assay that has not been studied in this context before.}},
  author       = {{Winstedt, Dag and Tynngård, Nahreen and Olanders, Knut and Schött, Ulf}},
  issn         = {{1757-7241}},
  keywords     = {{concentrate; Coagulation factor; Free oscillation rheometry; Thrombelastography; Fibrinogen; Factor XIII; Haemodilution; Hypothermia; Coagulopathy; Hydroxyethyl starch; Ringer's acetate solution}},
  language     = {{eng}},
  publisher    = {{BioMed Central (BMC)}},
  series       = {{Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine}},
  title        = {{Free oscillation rheometry monitoring of haemodilution and hypothermia and correction with fibrinogen and factor XIII concentrates.}},
  url          = {{https://lup.lub.lu.se/search/files/3257271/4025486.pdf}},
  doi          = {{10.1186/1757-7241-21-20}},
  volume       = {{21}},
  year         = {{2013}},
}