Continuous stand-alone controllable aerosol/cloud droplet dryer for atmospheric sampling

Sjögren, Staffan LU ; Frank, Göran LU orcid ; Berghof, Maria LU and Martinsson, Bengt LU (2013) In Atmospheric Measurement Techniques 6(2). p.349-357
Abstract
We describe a general-purpose dryer designed for continuous sampling of atmospheric aerosol, where a specified relative humidity (RH) of the sample flow (lower than the atmospheric humidity) is required. It is often prescribed to measure the properties of dried aerosol, for instance for monitoring networks. The specific purpose of our dryer is to dry cloud droplets (maximum diameter approximately 25 mu m, highly charged, up to 5x10(2) charges). One criterion is to minimise losses from the droplet size distribution entering the dryer as well as on the residual dry particle size distribution exiting the dryer. This is achieved by using a straight vertical downwards path from the aerosol inlet mounted above the dryer, and removing humidity to... (More)
We describe a general-purpose dryer designed for continuous sampling of atmospheric aerosol, where a specified relative humidity (RH) of the sample flow (lower than the atmospheric humidity) is required. It is often prescribed to measure the properties of dried aerosol, for instance for monitoring networks. The specific purpose of our dryer is to dry cloud droplets (maximum diameter approximately 25 mu m, highly charged, up to 5x10(2) charges). One criterion is to minimise losses from the droplet size distribution entering the dryer as well as on the residual dry particle size distribution exiting the dryer. This is achieved by using a straight vertical downwards path from the aerosol inlet mounted above the dryer, and removing humidity to a dry, closed loop airflow on the other side of a semi-permeable GORE-TEX membrane (total area 0.134m(2)). The water vapour transfer coefficient, k, was measured to be 4.6x10(-7) kgm(-2) s(-1) % RH-1 in the laboratory (temperature 294 K) and is used for design purposes. A net water vapour transfer rate of up to 1.2x10(-6) kg s-1 was achieved in the field. This corresponds to drying a 5.7 L min(-1) (0.35m(3) h(-1)) aerosol sample flow from 100% RH to 27% RH at 293K (with a drying air total flow of 8.7 L min-1). The system was used outdoors from 9 May until 20 October 2010, on the mountain Brocken (51.80 degrees N, 10.67 degrees E, 1142ma.s.l.) in the Harz region in central Germany. Sample air relative humidity of less than 30% was obtained 72% of the time period. The total availability of the measurement system was > 94% during these five months. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Atmospheric Measurement Techniques
volume
6
issue
2
pages
349 - 357
publisher
Copernicus GmbH
external identifiers
  • wos:000317011000015
  • scopus:84873920778
ISSN
1867-1381
DOI
10.5194/amt-6-349-2013
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007)
id
e7c80880-2a3d-49d0-8997-b82d69aae522 (old id 3748259)
date added to LUP
2016-04-01 10:22:07
date last changed
2022-01-25 22:35:32
@article{e7c80880-2a3d-49d0-8997-b82d69aae522,
  abstract     = {{We describe a general-purpose dryer designed for continuous sampling of atmospheric aerosol, where a specified relative humidity (RH) of the sample flow (lower than the atmospheric humidity) is required. It is often prescribed to measure the properties of dried aerosol, for instance for monitoring networks. The specific purpose of our dryer is to dry cloud droplets (maximum diameter approximately 25 mu m, highly charged, up to 5x10(2) charges). One criterion is to minimise losses from the droplet size distribution entering the dryer as well as on the residual dry particle size distribution exiting the dryer. This is achieved by using a straight vertical downwards path from the aerosol inlet mounted above the dryer, and removing humidity to a dry, closed loop airflow on the other side of a semi-permeable GORE-TEX membrane (total area 0.134m(2)). The water vapour transfer coefficient, k, was measured to be 4.6x10(-7) kgm(-2) s(-1) % RH-1 in the laboratory (temperature 294 K) and is used for design purposes. A net water vapour transfer rate of up to 1.2x10(-6) kg s-1 was achieved in the field. This corresponds to drying a 5.7 L min(-1) (0.35m(3) h(-1)) aerosol sample flow from 100% RH to 27% RH at 293K (with a drying air total flow of 8.7 L min-1). The system was used outdoors from 9 May until 20 October 2010, on the mountain Brocken (51.80 degrees N, 10.67 degrees E, 1142ma.s.l.) in the Harz region in central Germany. Sample air relative humidity of less than 30% was obtained 72% of the time period. The total availability of the measurement system was > 94% during these five months.}},
  author       = {{Sjögren, Staffan and Frank, Göran and Berghof, Maria and Martinsson, Bengt}},
  issn         = {{1867-1381}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{349--357}},
  publisher    = {{Copernicus GmbH}},
  series       = {{Atmospheric Measurement Techniques}},
  title        = {{Continuous stand-alone controllable aerosol/cloud droplet dryer for atmospheric sampling}},
  url          = {{http://dx.doi.org/10.5194/amt-6-349-2013}},
  doi          = {{10.5194/amt-6-349-2013}},
  volume       = {{6}},
  year         = {{2013}},
}