Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Diagnostic Accuracy of High-Sensitivity Cardiac Troponin T at Presentation Combined With History and ECG for Ruling Out Major Adverse Cardiac Events

MOKHTARI, ARASH LU ; Lindahl, Bertil ; Smith, J. Gustav ; Holzmann, Martin J. ; Khoshnood, Ardavan LU orcid and Ekelund, Ulf LU orcid (2016) In Annals of Emergency Medicine 68(6). p.649-658
Abstract

Study objective: We evaluate the diagnostic accuracy of a high-sensitivity cardiac troponin T (hs-cTnT) level less than 5 ng/L or less than or equal to 14 ng/L at emergency department (ED) presentation, combined with the emergency physician's assessment of history and ECG, for ruling out major adverse cardiac events within 30 days. Methods: This prospective observational study enrolled consecutive ED chest pain patients. Emergency physicians' assessments of patient history and ECG were collected. The primary outcome was 30-day major adverse cardiac events, defined as acute myocardial infarction, unstable angina, cardiogenic shock, ventricular arrhythmia, atrioventricular block, cardiac arrest, or death of cardiac or unknown cause.... (More)

Study objective: We evaluate the diagnostic accuracy of a high-sensitivity cardiac troponin T (hs-cTnT) level less than 5 ng/L or less than or equal to 14 ng/L at emergency department (ED) presentation, combined with the emergency physician's assessment of history and ECG, for ruling out major adverse cardiac events within 30 days. Methods: This prospective observational study enrolled consecutive ED chest pain patients. Emergency physicians' assessments of patient history and ECG were collected. The primary outcome was 30-day major adverse cardiac events, defined as acute myocardial infarction, unstable angina, cardiogenic shock, ventricular arrhythmia, atrioventricular block, cardiac arrest, or death of cardiac or unknown cause. Results: A total of 1,138 patients were included in the final analysis. The combination of hs-cTnT less than 5 ng/L, a nonischemic ECG result, and a nonhigh risk history was present for 29.2% of all patients and had a sensitivity of 99.2% (95% confidence interval [CI] 95.6% to 100%), negative predictive value (NPV) of 99.7% (95% CI 98.3% to 100%), and a negative likelihood ratio of 0.02 (95% CI 0 to 0.17) for 30-day major adverse cardiac events. The same combination with hs-cTnT less than or equal to 14 ng/L was present in 66.7% of the patients and had a sensitivity of 92% (95% CI 85.8% to 96.1%), NPV of 98.7% (95% CI 97.6% to 99.4%), and negative likelihood ratio of 0.11 (95% CI 0.06 to 0.20). Conclusion: A single hs-cTnT result of less than 5 ng/L at ED presentation when combined with a nonischemic ECG result and a nonhigh risk history identified 29% of chest pain patients at a very low risk of 30-day major adverse cardiac events. A similar strategy with hs-cTnT less than or equal to 14 ng/L was associated with a higher miss rate.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
TnT, Troponin T, Chest Pain, Acute Coronary Syndrome, Myocardial Infarction, TnT, Troponin T, Bröstsmärta, Akut Koronart Syndrom, Hjärtinfarkt
in
Annals of Emergency Medicine
volume
68
issue
6
pages
10 pages
publisher
Elsevier
external identifiers
  • pmid:27471140
  • wos:000389164800003
  • scopus:84979707948
ISSN
0196-0644
DOI
10.1016/j.annemergmed.2016.06.008
project
AIR Lund Chest pain - More efficient and equal emergency care with advanced medical decision support tools
language
English
LU publication?
yes
id
3a628132-8a29-4efe-ac4e-56aecb3a3224
date added to LUP
2016-09-08 15:53:25
date last changed
2024-01-04 12:08:44
@article{3a628132-8a29-4efe-ac4e-56aecb3a3224,
  abstract     = {{<p>Study objective: We evaluate the diagnostic accuracy of a high-sensitivity cardiac troponin T (hs-cTnT) level less than 5 ng/L or less than or equal to 14 ng/L at emergency department (ED) presentation, combined with the emergency physician's assessment of history and ECG, for ruling out major adverse cardiac events within 30 days. Methods: This prospective observational study enrolled consecutive ED chest pain patients. Emergency physicians' assessments of patient history and ECG were collected. The primary outcome was 30-day major adverse cardiac events, defined as acute myocardial infarction, unstable angina, cardiogenic shock, ventricular arrhythmia, atrioventricular block, cardiac arrest, or death of cardiac or unknown cause. Results: A total of 1,138 patients were included in the final analysis. The combination of hs-cTnT less than 5 ng/L, a nonischemic ECG result, and a nonhigh risk history was present for 29.2% of all patients and had a sensitivity of 99.2% (95% confidence interval [CI] 95.6% to 100%), negative predictive value (NPV) of 99.7% (95% CI 98.3% to 100%), and a negative likelihood ratio of 0.02 (95% CI 0 to 0.17) for 30-day major adverse cardiac events. The same combination with hs-cTnT less than or equal to 14 ng/L was present in 66.7% of the patients and had a sensitivity of 92% (95% CI 85.8% to 96.1%), NPV of 98.7% (95% CI 97.6% to 99.4%), and negative likelihood ratio of 0.11 (95% CI 0.06 to 0.20). Conclusion: A single hs-cTnT result of less than 5 ng/L at ED presentation when combined with a nonischemic ECG result and a nonhigh risk history identified 29% of chest pain patients at a very low risk of 30-day major adverse cardiac events. A similar strategy with hs-cTnT less than or equal to 14 ng/L was associated with a higher miss rate.</p>}},
  author       = {{MOKHTARI, ARASH and Lindahl, Bertil and Smith, J. Gustav and Holzmann, Martin J. and Khoshnood, Ardavan and Ekelund, Ulf}},
  issn         = {{0196-0644}},
  keywords     = {{TnT; Troponin T; Chest Pain; Acute Coronary Syndrome; Myocardial Infarction; TnT; Troponin T; Bröstsmärta; Akut Koronart Syndrom; Hjärtinfarkt}},
  language     = {{eng}},
  month        = {{03}},
  number       = {{6}},
  pages        = {{649--658}},
  publisher    = {{Elsevier}},
  series       = {{Annals of Emergency Medicine}},
  title        = {{Diagnostic Accuracy of High-Sensitivity Cardiac Troponin T at Presentation Combined With History and ECG for Ruling Out Major Adverse Cardiac Events}},
  url          = {{http://dx.doi.org/10.1016/j.annemergmed.2016.06.008}},
  doi          = {{10.1016/j.annemergmed.2016.06.008}},
  volume       = {{68}},
  year         = {{2016}},
}