Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Simulated sample heating from a nanofocused X-ray beam

Wallander, Harald LU and Wallentin, Jesper LU (2017) In Journal of Synchrotron Radiation 24(5). p.925-933
Abstract

Recent developments in synchrotron brilliance and X-ray optics are pushing the flux density in nanofocusing experiments to unprecedented levels, which increases the risk of different types of radiation damage. The effect of X-ray induced sample heating has been investigated using time-resolved and steady-state three-dimensional finite-element modelling of representative nanostructures. Simulations of a semiconductor nanowire indicate that the heat generated by X-ray absorption is efficiently transported within the nanowire, and that the temperature becomes homogeneous after about 5ns. The most important channel for heat loss is conduction to the substrate, where the heat transfer coefficient and the interfacial area are limiting the... (More)

Recent developments in synchrotron brilliance and X-ray optics are pushing the flux density in nanofocusing experiments to unprecedented levels, which increases the risk of different types of radiation damage. The effect of X-ray induced sample heating has been investigated using time-resolved and steady-state three-dimensional finite-element modelling of representative nanostructures. Simulations of a semiconductor nanowire indicate that the heat generated by X-ray absorption is efficiently transported within the nanowire, and that the temperature becomes homogeneous after about 5ns. The most important channel for heat loss is conduction to the substrate, where the heat transfer coefficient and the interfacial area are limiting the heat transport. While convective heat transfer to air is significant, the thermal radiation is negligible. The steady-state average temperature in the nanowire is 8K above room temperature at the reference parameters. In the absence of heat transfer to the substrate, the temperature increase at the same flux reaches 55K in air and far beyond the melting temperature in vacuum. Reducing the size of the X-ray focus at constant flux only increases the maximum temperature marginally. These results suggest that the key strategy for reducing the X-ray induced heating is to improve the heat transfer to the surrounding.Time-resolved finite-element modelling is used to study the sample heating from intense X-ray irradiation.

(Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
heating, nanostructures, radiation damage, simulation
in
Journal of Synchrotron Radiation
volume
24
issue
5
pages
9 pages
publisher
International Union of Crystallography
external identifiers
  • scopus:85028723593
  • pmid:28862614
  • wos:000408902800005
ISSN
0909-0495
DOI
10.1107/S1600577517008712
language
English
LU publication?
yes
id
3c196f7b-aa8d-483d-af5e-d155f5486988
date added to LUP
2017-09-26 11:13:53
date last changed
2024-04-14 18:14:50
@article{3c196f7b-aa8d-483d-af5e-d155f5486988,
  abstract     = {{<p>Recent developments in synchrotron brilliance and X-ray optics are pushing the flux density in nanofocusing experiments to unprecedented levels, which increases the risk of different types of radiation damage. The effect of X-ray induced sample heating has been investigated using time-resolved and steady-state three-dimensional finite-element modelling of representative nanostructures. Simulations of a semiconductor nanowire indicate that the heat generated by X-ray absorption is efficiently transported within the nanowire, and that the temperature becomes homogeneous after about 5ns. The most important channel for heat loss is conduction to the substrate, where the heat transfer coefficient and the interfacial area are limiting the heat transport. While convective heat transfer to air is significant, the thermal radiation is negligible. The steady-state average temperature in the nanowire is 8K above room temperature at the reference parameters. In the absence of heat transfer to the substrate, the temperature increase at the same flux reaches 55K in air and far beyond the melting temperature in vacuum. Reducing the size of the X-ray focus at constant flux only increases the maximum temperature marginally. These results suggest that the key strategy for reducing the X-ray induced heating is to improve the heat transfer to the surrounding.Time-resolved finite-element modelling is used to study the sample heating from intense X-ray irradiation.</p>}},
  author       = {{Wallander, Harald and Wallentin, Jesper}},
  issn         = {{0909-0495}},
  keywords     = {{heating; nanostructures; radiation damage; simulation}},
  language     = {{eng}},
  month        = {{09}},
  number       = {{5}},
  pages        = {{925--933}},
  publisher    = {{International Union of Crystallography}},
  series       = {{Journal of Synchrotron Radiation}},
  title        = {{Simulated sample heating from a nanofocused X-ray beam}},
  url          = {{http://dx.doi.org/10.1107/S1600577517008712}},
  doi          = {{10.1107/S1600577517008712}},
  volume       = {{24}},
  year         = {{2017}},
}