Helical differential X-ray phase-contrast computed tomography.

Fu, Jian ; Willner, Marian ; Chen, Liyuan ; Tan, Renbo ; Achterhold, Klaus ; Bech, Martin LU orcid ; Herzen, Julia ; Kunka, Danays ; Mohr, Juergen and Pfeiffer, Franz (2014) In Physica Medica 30(3). p.374-379
Abstract
We report on the first experimental results of helical differential phase-contrast computed tomography (helical DPC-CT) with a laboratory X-ray tube source and a Talbot-Lau grating interferometer. The results experimentally verify the feasibility of helical data acquisition and reconstruction in phase-contrast imaging, in analogy to its use in clinical CT systems. This allows fast and continuous volumetric scans for long objects with lengths exceeding the dimension of the detector. Since helical CT revolutionized the field of medical CT several years ago, we anticipate that this method will bring the same significant impact on the future medical and industrial applications of X-ray DPC-CT.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Physica Medica
volume
30
issue
3
pages
374 - 379
publisher
ISTITUTI EDITORIALI E POLGRAFICI INTERNAZIONALI
external identifiers
  • pmid:24518822
  • wos:000334094200017
  • scopus:84896069067
  • pmid:24518822
ISSN
1120-1797
DOI
10.1016/j.ejmp.2014.01.005
language
English
LU publication?
yes
id
f26ab1b8-22d5-43b3-bb2c-e78a3c4e7cbb (old id 4334824)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/24518822?dopt=Abstract
date added to LUP
2016-04-01 11:16:59
date last changed
2022-04-28 08:40:06
@article{f26ab1b8-22d5-43b3-bb2c-e78a3c4e7cbb,
  abstract     = {{We report on the first experimental results of helical differential phase-contrast computed tomography (helical DPC-CT) with a laboratory X-ray tube source and a Talbot-Lau grating interferometer. The results experimentally verify the feasibility of helical data acquisition and reconstruction in phase-contrast imaging, in analogy to its use in clinical CT systems. This allows fast and continuous volumetric scans for long objects with lengths exceeding the dimension of the detector. Since helical CT revolutionized the field of medical CT several years ago, we anticipate that this method will bring the same significant impact on the future medical and industrial applications of X-ray DPC-CT.}},
  author       = {{Fu, Jian and Willner, Marian and Chen, Liyuan and Tan, Renbo and Achterhold, Klaus and Bech, Martin and Herzen, Julia and Kunka, Danays and Mohr, Juergen and Pfeiffer, Franz}},
  issn         = {{1120-1797}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{374--379}},
  publisher    = {{ISTITUTI EDITORIALI E POLGRAFICI INTERNAZIONALI}},
  series       = {{Physica Medica}},
  title        = {{Helical differential X-ray phase-contrast computed tomography.}},
  url          = {{http://dx.doi.org/10.1016/j.ejmp.2014.01.005}},
  doi          = {{10.1016/j.ejmp.2014.01.005}},
  volume       = {{30}},
  year         = {{2014}},
}