Comparing charcoal and zeolite reflection filters for volatile anaesthetics: A laboratory evaluation.

Walther Sturesson, Louise LU ; Frennström, Jan O ; Ilardi, Marcella and Reinstrup, Peter LU (2015) In European Journal of Anaesthesiology 32(8). p.521-526
Abstract
A modified heat-moisture exchanger that incorporates a reflecting filter for use with partial rebreathing of exhaled volatile anaesthetics has been commercially available since the 1990s. The main advantages of the device are efficient delivery of inhaled sedation to intensive care patients and reduced anaesthetic consumption during anaesthesia. However, elevated arterial CO2 values have been observed with an anaesthetic conserving device compared with a conventional heat and moisture exchanger, despite compensation for larger apparatus dead space.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
European Journal of Anaesthesiology
volume
32
issue
8
pages
521 - 526
publisher
European Society of Anaesthesiology
external identifiers
  • pmid:25387299
  • wos:000358288400002
  • scopus:84937953188
  • pmid:25387299
ISSN
1365-2346
DOI
10.1097/EJA.0000000000000177
language
English
LU publication?
yes
id
36ad24e6-ebe5-48fb-a707-3c13bd722529 (old id 4816968)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/25387299?dopt=Abstract
date added to LUP
2016-04-01 11:03:21
date last changed
2022-04-12 20:04:50
@article{36ad24e6-ebe5-48fb-a707-3c13bd722529,
  abstract     = {{A modified heat-moisture exchanger that incorporates a reflecting filter for use with partial rebreathing of exhaled volatile anaesthetics has been commercially available since the 1990s. The main advantages of the device are efficient delivery of inhaled sedation to intensive care patients and reduced anaesthetic consumption during anaesthesia. However, elevated arterial CO2 values have been observed with an anaesthetic conserving device compared with a conventional heat and moisture exchanger, despite compensation for larger apparatus dead space.}},
  author       = {{Walther Sturesson, Louise and Frennström, Jan O and Ilardi, Marcella and Reinstrup, Peter}},
  issn         = {{1365-2346}},
  language     = {{eng}},
  number       = {{8}},
  pages        = {{521--526}},
  publisher    = {{European Society of Anaesthesiology}},
  series       = {{European Journal of Anaesthesiology}},
  title        = {{Comparing charcoal and zeolite reflection filters for volatile anaesthetics: A laboratory evaluation.}},
  url          = {{http://dx.doi.org/10.1097/EJA.0000000000000177}},
  doi          = {{10.1097/EJA.0000000000000177}},
  volume       = {{32}},
  year         = {{2015}},
}