Influence of wall ribs on the thermal stratification and self-pressurization in a cryogenic liquid tank

Fu, Juan LU ; Sundén, Bengt LU and Chen, Xiaoqian (2014) In Applied Thermal Engineering 73(2). p.1421-1431
Abstract
Self-pressurization in a cylindrical ribbed tank which is partially filled with liquid hydrogen is investigated numerically under different rib spacing-to-height ratios. The Volume of Fluid (VOF) method is employed as well as a phase change model. Appropriate models are incorporated into the Ansys Fluent by the user-defined functions to carry out the computations. The ribbed surface is modeled as a finned surface and a conjugate transient heat transfer problem is formulated for predicting fluid flow currents and heat transfer. The effect of rib material and shapes is also studied. Numerical results indicate that the pressure rise can be reduced by ribs mounted on the tank wall. This phenomenon is more pronounced as the rib... (More)
Self-pressurization in a cylindrical ribbed tank which is partially filled with liquid hydrogen is investigated numerically under different rib spacing-to-height ratios. The Volume of Fluid (VOF) method is employed as well as a phase change model. Appropriate models are incorporated into the Ansys Fluent by the user-defined functions to carry out the computations. The ribbed surface is modeled as a finned surface and a conjugate transient heat transfer problem is formulated for predicting fluid flow currents and heat transfer. The effect of rib material and shapes is also studied. Numerical results indicate that the pressure rise can be reduced by ribs mounted on the tank wall. This phenomenon is more pronounced as the rib spacing-to-height ratio is reduced. A vortex is observed in the downstream region of each rib when the spacing-to-height has a relatively high value. Evaporation occurs as time elapses due to heat accumulation at the rib surfaces. Pressure starts to rise later with high thermal conductivity ribs and becomes higher with low thermal conductivity ribs when the ribs are of identical configuration in geometry. The final pressure rise seems to be monotonically versus increasing time. The semicircular ribs perform better than rectangular ones in control of the pressure rise and thermal stratification for identical cross sectional area and if the locations are kept the same. (C) 2014 Elsevier Ltd. All rights reserved. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Cryogenic liquid storage tank, Wall ribs, Thermal stratification, Pressure rise
in
Applied Thermal Engineering
volume
73
issue
2
pages
1421 - 1431
publisher
Elsevier
external identifiers
  • wos:000347502300004
  • scopus:84915798452
ISSN
1359-4311
DOI
10.1016/j.applthermaleng.2014.05.086
language
English
LU publication?
yes
id
9d36cdd7-b994-4af9-a456-09934e1b6b53 (old id 5076100)
date added to LUP
2016-04-01 09:56:24
date last changed
2022-04-27 08:57:47
@article{9d36cdd7-b994-4af9-a456-09934e1b6b53,
  abstract     = {{Self-pressurization in a cylindrical ribbed tank which is partially filled with liquid hydrogen is investigated numerically under different rib spacing-to-height ratios. The Volume of Fluid (VOF) method is employed as well as a phase change model. Appropriate models are incorporated into the Ansys Fluent by the user-defined functions to carry out the computations. The ribbed surface is modeled as a finned surface and a conjugate transient heat transfer problem is formulated for predicting fluid flow currents and heat transfer. The effect of rib material and shapes is also studied. Numerical results indicate that the pressure rise can be reduced by ribs mounted on the tank wall. This phenomenon is more pronounced as the rib spacing-to-height ratio is reduced. A vortex is observed in the downstream region of each rib when the spacing-to-height has a relatively high value. Evaporation occurs as time elapses due to heat accumulation at the rib surfaces. Pressure starts to rise later with high thermal conductivity ribs and becomes higher with low thermal conductivity ribs when the ribs are of identical configuration in geometry. The final pressure rise seems to be monotonically versus increasing time. The semicircular ribs perform better than rectangular ones in control of the pressure rise and thermal stratification for identical cross sectional area and if the locations are kept the same. (C) 2014 Elsevier Ltd. All rights reserved.}},
  author       = {{Fu, Juan and Sundén, Bengt and Chen, Xiaoqian}},
  issn         = {{1359-4311}},
  keywords     = {{Cryogenic liquid storage tank; Wall ribs; Thermal stratification; Pressure rise}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{1421--1431}},
  publisher    = {{Elsevier}},
  series       = {{Applied Thermal Engineering}},
  title        = {{Influence of wall ribs on the thermal stratification and self-pressurization in a cryogenic liquid tank}},
  url          = {{http://dx.doi.org/10.1016/j.applthermaleng.2014.05.086}},
  doi          = {{10.1016/j.applthermaleng.2014.05.086}},
  volume       = {{73}},
  year         = {{2014}},
}