The effect of femoral orientation on the measurement of the head shaft angle : an ex-vivo study

Wordie, Sarah J. ; Gaston, Mark S. ; Hägglund, Gunnar LU ; Czuba, Tomasz LU and Robb, James E. (2019) In Journal of Pediatric Orthopedics. Part B 28(5). p.465-469
Abstract

This laboratory study evaluates head shaft angle (HSA) reliability using ranges of simulated femoral orientation often seen in children with cerebral palsy. A dry femur was mounted in a jig that enabled the bone to be positioned in a range of internal and external rotation (-40° to + 40°) and flexion (0°-60°), alone or in combination. A metal wire was placed as a surrogate physis to give two HSA angles of 140° and 160°. Radiographs were taken of the femur in differing combinations of rotation, flexion and the two HSA angles. The HSA was measured by four independent observers on two separate occasions. Intraclass correlation coefficients (ICCs) were used to assess interobserver and intraobserver reliability. The HSA was accurately... (More)

This laboratory study evaluates head shaft angle (HSA) reliability using ranges of simulated femoral orientation often seen in children with cerebral palsy. A dry femur was mounted in a jig that enabled the bone to be positioned in a range of internal and external rotation (-40° to + 40°) and flexion (0°-60°), alone or in combination. A metal wire was placed as a surrogate physis to give two HSA angles of 140° and 160°. Radiographs were taken of the femur in differing combinations of rotation, flexion and the two HSA angles. The HSA was measured by four independent observers on two separate occasions. Intraclass correlation coefficients (ICCs) were used to assess interobserver and intraobserver reliability. The HSA was accurately measured within ± 5° when the femur was positioned between 20° internal rotation and 40° external rotation. Flexion up to 60° did not affect the accuracy of the measurement. The interobserver reliability for the HSA was excellent with an ICC of 0.9970 [95% confidence interval (CI): 0.9995-0.9983] for the first measurement and 0.9988 for the second (95% CI: 0.9979-0.9993, all P < 0.01). The intraobserver reliability was also excellent with an ICC of not less than 0.990 for all four observers (95% CI: 0.9806-0.9986, all P < 0.01). There was excellent interobserver and intraobserver reliability when measuring the HSA in an experimental model provided femoral rotation lay within 20° internal and 40° external rotation and less than 60° of flexion.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Pediatric Orthopedics. Part B
volume
28
issue
5
pages
5 pages
publisher
Lippincott Williams & Wilkins
external identifiers
  • pmid:30789536
  • scopus:85070634846
ISSN
1473-5865
DOI
10.1097/BPB.0000000000000608
language
English
LU publication?
yes
id
5d920319-8acb-48f1-93b6-4e920a85b4fa
date added to LUP
2019-08-30 10:36:08
date last changed
2024-03-03 22:51:34
@article{5d920319-8acb-48f1-93b6-4e920a85b4fa,
  abstract     = {{<p>This laboratory study evaluates head shaft angle (HSA) reliability using ranges of simulated femoral orientation often seen in children with cerebral palsy. A dry femur was mounted in a jig that enabled the bone to be positioned in a range of internal and external rotation (-40° to + 40°) and flexion (0°-60°), alone or in combination. A metal wire was placed as a surrogate physis to give two HSA angles of 140° and 160°. Radiographs were taken of the femur in differing combinations of rotation, flexion and the two HSA angles. The HSA was measured by four independent observers on two separate occasions. Intraclass correlation coefficients (ICCs) were used to assess interobserver and intraobserver reliability. The HSA was accurately measured within ± 5° when the femur was positioned between 20° internal rotation and 40° external rotation. Flexion up to 60° did not affect the accuracy of the measurement. The interobserver reliability for the HSA was excellent with an ICC of 0.9970 [95% confidence interval (CI): 0.9995-0.9983] for the first measurement and 0.9988 for the second (95% CI: 0.9979-0.9993, all P &lt; 0.01). The intraobserver reliability was also excellent with an ICC of not less than 0.990 for all four observers (95% CI: 0.9806-0.9986, all P &lt; 0.01). There was excellent interobserver and intraobserver reliability when measuring the HSA in an experimental model provided femoral rotation lay within 20° internal and 40° external rotation and less than 60° of flexion.</p>}},
  author       = {{Wordie, Sarah J. and Gaston, Mark S. and Hägglund, Gunnar and Czuba, Tomasz and Robb, James E.}},
  issn         = {{1473-5865}},
  language     = {{eng}},
  month        = {{09}},
  number       = {{5}},
  pages        = {{465--469}},
  publisher    = {{Lippincott Williams & Wilkins}},
  series       = {{Journal of Pediatric Orthopedics. Part B}},
  title        = {{The effect of femoral orientation on the measurement of the head shaft angle : an ex-vivo study}},
  url          = {{http://dx.doi.org/10.1097/BPB.0000000000000608}},
  doi          = {{10.1097/BPB.0000000000000608}},
  volume       = {{28}},
  year         = {{2019}},
}