New non-invasive method for intima-media thickness and intima-media compression measurements
(2005) IEEE Ultrasonics Symposium, 2005 1. p.389-392- Abstract
- Intim a-media thickness (IMT) is considered as a valuable marker of early atherosclerosis. We suggest a new algorithm for simultaneous measurements of absolute diameter at diastole, distension (diameter change), IMT at diastole and the intima-media compression (IMC) with a new fast, robust, high-resolution, and automatic algorithm utilizing the ultrasonic gray-scale information. The new algorithm is evaluated in a limited in vivo study on the common carotid artery of 5 healthy volunteers. The standard deviation within an investigation was (8 ± 4 μm; range 4-14 μm) during IMC measurements, (8 ± 5 μm; range 4-16 μm) during the measurements of the IMT at diastole, (30 ±36 μm; range 6-92 μm) during the distension measurements and (48 ±49 μm;... (More)
- Intim a-media thickness (IMT) is considered as a valuable marker of early atherosclerosis. We suggest a new algorithm for simultaneous measurements of absolute diameter at diastole, distension (diameter change), IMT at diastole and the intima-media compression (IMC) with a new fast, robust, high-resolution, and automatic algorithm utilizing the ultrasonic gray-scale information. The new algorithm is evaluated in a limited in vivo study on the common carotid artery of 5 healthy volunteers. The standard deviation within an investigation was (8 ± 4 μm; range 4-14 μm) during IMC measurements, (8 ± 5 μm; range 4-16 μm) during the measurements of the IMT at diastole, (30 ±36 μm; range 6-92 μm) during the distension measurements and (48 ±49 μm; range 15-134 μm) during the measurements of the lumen diameter at diastole. The evaluation shows that the algorithm is fast and that the reproducibility and resolution are more than sufficient for in vivo studies. © 2005 IEEE. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/615694
- author
- Cinthio, Magnus LU ; Jansson, Tomas LU ; Persson, Hans W LU ; Lindström, Kjell LU and Rydén Ahlgren, Åsa LU
- organization
- publishing date
- 2005
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Lumen diameter, Common carotid artery, Intima media thickness (IMT), Intima media compression (IMC)
- host publication
- Proceedings - IEEE Ultrasonics Symposium
- volume
- 1
- pages
- 389 - 392
- publisher
- IEEE - Institute of Electrical and Electronics Engineers Inc.
- conference name
- IEEE Ultrasonics Symposium, 2005
- conference location
- Rotterdam, Netherlands
- conference dates
- 2005-09-18 - 2005-09-21
- external identifiers
-
- wos:000236090700095
- scopus:33847109679
- ISSN
- 1051-0117
- ISBN
- 0780393821
- DOI
- 10.1109/ULTSYM.2005.1602875
- language
- English
- LU publication?
- yes
- id
- 4dec876e-d1af-4041-a055-eaa2694bb63f (old id 615694)
- date added to LUP
- 2016-04-01 17:01:39
- date last changed
- 2023-09-05 05:49:21
@inproceedings{4dec876e-d1af-4041-a055-eaa2694bb63f, abstract = {{Intim a-media thickness (IMT) is considered as a valuable marker of early atherosclerosis. We suggest a new algorithm for simultaneous measurements of absolute diameter at diastole, distension (diameter change), IMT at diastole and the intima-media compression (IMC) with a new fast, robust, high-resolution, and automatic algorithm utilizing the ultrasonic gray-scale information. The new algorithm is evaluated in a limited in vivo study on the common carotid artery of 5 healthy volunteers. The standard deviation within an investigation was (8 ± 4 μm; range 4-14 μm) during IMC measurements, (8 ± 5 μm; range 4-16 μm) during the measurements of the IMT at diastole, (30 ±36 μm; range 6-92 μm) during the distension measurements and (48 ±49 μm; range 15-134 μm) during the measurements of the lumen diameter at diastole. The evaluation shows that the algorithm is fast and that the reproducibility and resolution are more than sufficient for in vivo studies. © 2005 IEEE.}}, author = {{Cinthio, Magnus and Jansson, Tomas and Persson, Hans W and Lindström, Kjell and Rydén Ahlgren, Åsa}}, booktitle = {{Proceedings - IEEE Ultrasonics Symposium}}, isbn = {{0780393821}}, issn = {{1051-0117}}, keywords = {{Lumen diameter; Common carotid artery; Intima media thickness (IMT); Intima media compression (IMC)}}, language = {{eng}}, pages = {{389--392}}, publisher = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}}, title = {{New non-invasive method for intima-media thickness and intima-media compression measurements}}, url = {{http://dx.doi.org/10.1109/ULTSYM.2005.1602875}}, doi = {{10.1109/ULTSYM.2005.1602875}}, volume = {{1}}, year = {{2005}}, }