Temperature evaluation of soft and hard PZT transducers for ultrasonic

Johansson, Linda ; Evander, Mikael LU ; Lilliehorn, Tobias ; Almqvist, Monica LU ; Nilsson, Johan LU ; Laurell, Thomas LU and Johansson, Stefan (2005) Micro Total Analysis Systems 2005 2. p.1428-1430
Abstract
This paper reports a comparison of soft and hard piezoceramic transducer materials used for ultrasonic particle trapping in a microfluidic bioanalytical platform. The investigation is made with the objective to obtain high acoustic forces with a minimum of temperature increase. Themperature is a critical parameter for bioassays and most often need to be kept below a certain level to allow handling of e.g. temperature sensitive proteins. The main conclusion in this paper is that it is possible to get efficieint trapping with a temperature increase of only a few degrees using a hard type III transducer material.
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
Acoustic trapping, temperature, piezoceramic transducer, bioanalysis
host publication
Proceedings of µTAS 2005 Conference
editor
Jensen, Klavs F. ; Han, Jongyoon ; Harrison, D. Jed and Voldman, Joel
volume
2
pages
3 pages
publisher
Transducer Research Foundation
conference name
Micro Total Analysis Systems 2005
conference location
Boston, United States
conference dates
2005-10-09 - 2005-10-13
external identifiers
  • scopus:84902519658
ISBN
0-9743611-1-9
language
English
LU publication?
yes
id
1aaea611-aea9-4553-9a29-66f2c040f707 (old id 789708)
date added to LUP
2016-04-04 12:02:23
date last changed
2022-01-29 22:47:17
@inproceedings{1aaea611-aea9-4553-9a29-66f2c040f707,
  abstract     = {{This paper reports a comparison of soft and hard piezoceramic transducer materials used for ultrasonic particle trapping in a microfluidic bioanalytical platform. The investigation is made with the objective to obtain high acoustic forces with a minimum of temperature increase. Themperature is a critical parameter for bioassays and most often need to be kept below a certain level to allow handling of e.g. temperature sensitive proteins. The main conclusion in this paper is that it is possible to get efficieint trapping with a temperature increase of only a few degrees using a hard type III transducer material.}},
  author       = {{Johansson, Linda and Evander, Mikael and Lilliehorn, Tobias and Almqvist, Monica and Nilsson, Johan and Laurell, Thomas and Johansson, Stefan}},
  booktitle    = {{Proceedings of µTAS 2005 Conference}},
  editor       = {{Jensen, Klavs F. and Han, Jongyoon and Harrison, D. Jed and Voldman, Joel}},
  isbn         = {{0-9743611-1-9}},
  keywords     = {{Acoustic trapping; temperature; piezoceramic transducer; bioanalysis}},
  language     = {{eng}},
  pages        = {{1428--1430}},
  publisher    = {{Transducer Research Foundation}},
  title        = {{Temperature evaluation of soft and hard PZT transducers for ultrasonic}},
  volume       = {{2}},