Performance Comparison between Steam Injected Gas Turbine and Combined Cycle during Frequency Drops

Bahrami, Saeed ; Ghaffari, Ali ; Genrup, Magnus LU and Thern, Marcus LU (2015) In Energies 8(8). p.7582-7592
Abstract
Single-shaft gas turbine and its cycles are sensitive to frequency drops and, therefore, sudden change loads or large frequency dips might affect their stability. This phenomenon is related to the reduction of the air mass flow passing through the machine during the frequency dips, which might lead to an interaction between governor and temperature control loop. In this paper, the performance of the combined cycle and steam-injected gas turbine are studied during frequency dips and transient maneuvers. For this purpose, two similar units are developed based on these cycles and their performances are studied in different scenarios. The simulation results show that the steam injected gas turbine has a better performance during frequency... (More)
Single-shaft gas turbine and its cycles are sensitive to frequency drops and, therefore, sudden change loads or large frequency dips might affect their stability. This phenomenon is related to the reduction of the air mass flow passing through the machine during the frequency dips, which might lead to an interaction between governor and temperature control loop. In this paper, the performance of the combined cycle and steam-injected gas turbine are studied during frequency dips and transient maneuvers. For this purpose, two similar units are developed based on these cycles and their performances are studied in different scenarios. The simulation results show that the steam injected gas turbine has a better performance during frequency drops and it can handle relatively larger change loads. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
combined cycle, wet cycle, STIG turbine, frequency control
in
Energies
volume
8
issue
8
pages
7582 - 7592
publisher
MDPI AG
external identifiers
  • wos:000360586600004
  • scopus:84941729211
ISSN
1996-1073
DOI
10.3390/en8087582
language
English
LU publication?
yes
id
750d7b10-6a37-436e-be7f-e1c10434ea88 (old id 8077325)
date added to LUP
2016-04-01 14:00:53
date last changed
2022-02-27 00:21:36
@article{750d7b10-6a37-436e-be7f-e1c10434ea88,
  abstract     = {{Single-shaft gas turbine and its cycles are sensitive to frequency drops and, therefore, sudden change loads or large frequency dips might affect their stability. This phenomenon is related to the reduction of the air mass flow passing through the machine during the frequency dips, which might lead to an interaction between governor and temperature control loop. In this paper, the performance of the combined cycle and steam-injected gas turbine are studied during frequency dips and transient maneuvers. For this purpose, two similar units are developed based on these cycles and their performances are studied in different scenarios. The simulation results show that the steam injected gas turbine has a better performance during frequency drops and it can handle relatively larger change loads.}},
  author       = {{Bahrami, Saeed and Ghaffari, Ali and Genrup, Magnus and Thern, Marcus}},
  issn         = {{1996-1073}},
  keywords     = {{combined cycle; wet cycle; STIG turbine; frequency control}},
  language     = {{eng}},
  number       = {{8}},
  pages        = {{7582--7592}},
  publisher    = {{MDPI AG}},
  series       = {{Energies}},
  title        = {{Performance Comparison between Steam Injected Gas Turbine and Combined Cycle during Frequency Drops}},
  url          = {{http://dx.doi.org/10.3390/en8087582}},
  doi          = {{10.3390/en8087582}},
  volume       = {{8}},
  year         = {{2015}},
}