Characterization of undulator radiation at MAXII using a soft X-ray fluorescence spectrometer
(1999) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 431(1). p.285-293- Abstract
A grazing-incidence grating spectrometer has been used for the investigation of the undulator radiation from beamline 411 at MAX-lab. The direct detection of undulator light is expected to obtain the information of the quality of the undulator. Regular undulator radiation and some higher harmonics were observed. The effects of electronic beam coupling and Landau cavities have been studied. The experiment presents an easy and quick method to characterize the undulator radiation before the permanent monochromator is installed.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/b1584aec-c26e-4979-8e02-b82fe8855787
- author
- organization
- publishing date
- 1999-07-11
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 431
- issue
- 1
- pages
- 9 pages
- publisher
- Elsevier
- external identifiers
-
- scopus:18844467268
- ISSN
- 0168-9002
- DOI
- 10.1016/S0168-9002(99)00182-5
- language
- English
- LU publication?
- yes
- id
- b1584aec-c26e-4979-8e02-b82fe8855787
- date added to LUP
- 2016-04-27 16:43:43
- date last changed
- 2022-01-30 02:55:11
@article{b1584aec-c26e-4979-8e02-b82fe8855787, abstract = {{<p>A grazing-incidence grating spectrometer has been used for the investigation of the undulator radiation from beamline 411 at MAX-lab. The direct detection of undulator light is expected to obtain the information of the quality of the undulator. Regular undulator radiation and some higher harmonics were observed. The effects of electronic beam coupling and Landau cavities have been studied. The experiment presents an easy and quick method to characterize the undulator radiation before the permanent monochromator is installed.</p>}}, author = {{Guo, J. H. and Butorin, S. M. and Såthe, C. and Nordgren, J. and Bässler, M. and Feifel, R. and Werin, S. and Georgsson, M. and Andersson, Åke and Jurvansuu, M. and Nyholm, R. and Eriksson, M.}}, issn = {{0168-9002}}, language = {{eng}}, month = {{07}}, number = {{1}}, pages = {{285--293}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{Characterization of undulator radiation at MAXII using a soft X-ray fluorescence spectrometer}}, url = {{http://dx.doi.org/10.1016/S0168-9002(99)00182-5}}, doi = {{10.1016/S0168-9002(99)00182-5}}, volume = {{431}}, year = {{1999}}, }