Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Submicrometer-resolution photoelectron-spectroscopy at MAX Lab

Nyholm, R. LU ; Eriksson, M. LU ; Hansen, K. LU ; Sairanen, O. P. ; Werin, S. LU ; Flodström, A. ; Törnevik, C. ; Meinander, T. and Sarakontu, M. (1989) In Review of Scientific Instruments 60(7). p.2168-2171
Abstract

The design of a photoemission microprobe beamline at the MAX laboratory is presented. The beamline will utilize the radiation from a 26 period undulator on the 550-MeV MAX storage ring. The beamline will be capable of providing about 1010 photons/s of monochromatized radiation (bandwidth better than 0.25 eV) in the energy range of 20 to 150 eV focused into a submicrometer focal spot. It will be used for scanning photoemission experiments with a lateral resolution better than 1 μm. The optical system is comprised of a plane-grating monochromator with a Kirkpatrick-Baez objective and a specially designed ellipsoidal focusing mirror.

Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
in
Review of Scientific Instruments
volume
60
issue
7
pages
4 pages
publisher
American Institute of Physics (AIP)
external identifiers
  • scopus:0042066916
ISSN
0034-6748
DOI
10.1063/1.1140812
language
English
LU publication?
yes
id
b1db18b2-0346-48a0-b873-99cd5e871540
date added to LUP
2016-08-19 11:04:01
date last changed
2021-12-29 08:03:34
@article{b1db18b2-0346-48a0-b873-99cd5e871540,
  abstract     = {{<p>The design of a photoemission microprobe beamline at the MAX laboratory is presented. The beamline will utilize the radiation from a 26 period undulator on the 550-MeV MAX storage ring. The beamline will be capable of providing about 10<sup>10</sup> photons/s of monochromatized radiation (bandwidth better than 0.25 eV) in the energy range of 20 to 150 eV focused into a submicrometer focal spot. It will be used for scanning photoemission experiments with a lateral resolution better than 1 μm. The optical system is comprised of a plane-grating monochromator with a Kirkpatrick-Baez objective and a specially designed ellipsoidal focusing mirror.</p>}},
  author       = {{Nyholm, R. and Eriksson, M. and Hansen, K. and Sairanen, O. P. and Werin, S. and Flodström, A. and Törnevik, C. and Meinander, T. and Sarakontu, M.}},
  issn         = {{0034-6748}},
  language     = {{eng}},
  number       = {{7}},
  pages        = {{2168--2171}},
  publisher    = {{American Institute of Physics (AIP)}},
  series       = {{Review of Scientific Instruments}},
  title        = {{Submicrometer-resolution photoelectron-spectroscopy at MAX Lab}},
  url          = {{http://dx.doi.org/10.1063/1.1140812}},
  doi          = {{10.1063/1.1140812}},
  volume       = {{60}},
  year         = {{1989}},
}