Effects of deposition locations on film cooling with and without a mist injection

Wang, Jin ; Cui, Pei ; Sundén, Bengt LU and Yang, Ran (2016) In Numerical Heat Transfer; Part A: Applications 70(10). p.1072-1086
Abstract

The adiabatic film-cooling effectiveness on a thermal barrier coating surface is investigated numerically. A film-cooling hole with an inclination angle of 35° is placed upstream the deposition configuration. The depositions are arranged on the external wall with three different positions. For no-mist models, the cooling performances downstream the wall are investigated for the blowing ratios of 0.5, 0.75, and 1.0. Results show that the adiabatic film-cooling effectiveness without surface deposition is decreased by increasing the blowing ratio. To investigate the effects of both different locations and 4.4% mist injection on the film cooling, a discrete phase model (DPM) is used. It is found that the film-cooling effectiveness is... (More)

The adiabatic film-cooling effectiveness on a thermal barrier coating surface is investigated numerically. A film-cooling hole with an inclination angle of 35° is placed upstream the deposition configuration. The depositions are arranged on the external wall with three different positions. For no-mist models, the cooling performances downstream the wall are investigated for the blowing ratios of 0.5, 0.75, and 1.0. Results show that the adiabatic film-cooling effectiveness without surface deposition is decreased by increasing the blowing ratio. To investigate the effects of both different locations and 4.4% mist injection on the film cooling, a discrete phase model (DPM) is used. It is found that the film-cooling effectiveness is improved remarkably from the deposition position to the wall downstream. In addition, deposition formation at the middle location shows a good cooling effectiveness, but the lowest value of the film-cooling effectiveness occurs upstream the deposition position.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Numerical Heat Transfer; Part A: Applications
volume
70
issue
10
pages
15 pages
publisher
Taylor & Francis
external identifiers
  • wos:000388424600002
  • scopus:84992073964
ISSN
1040-7782
DOI
10.1080/10407782.2016.1230395
language
English
LU publication?
yes
id
b6f21777-fc14-4e59-ad43-6dd13c7f52f6
date added to LUP
2016-11-09 09:19:57
date last changed
2024-01-04 16:04:37
@article{b6f21777-fc14-4e59-ad43-6dd13c7f52f6,
  abstract     = {{<p>The adiabatic film-cooling effectiveness on a thermal barrier coating surface is investigated numerically. A film-cooling hole with an inclination angle of 35° is placed upstream the deposition configuration. The depositions are arranged on the external wall with three different positions. For no-mist models, the cooling performances downstream the wall are investigated for the blowing ratios of 0.5, 0.75, and 1.0. Results show that the adiabatic film-cooling effectiveness without surface deposition is decreased by increasing the blowing ratio. To investigate the effects of both different locations and 4.4% mist injection on the film cooling, a discrete phase model (DPM) is used. It is found that the film-cooling effectiveness is improved remarkably from the deposition position to the wall downstream. In addition, deposition formation at the middle location shows a good cooling effectiveness, but the lowest value of the film-cooling effectiveness occurs upstream the deposition position.</p>}},
  author       = {{Wang, Jin and Cui, Pei and Sundén, Bengt and Yang, Ran}},
  issn         = {{1040-7782}},
  language     = {{eng}},
  number       = {{10}},
  pages        = {{1072--1086}},
  publisher    = {{Taylor & Francis}},
  series       = {{Numerical Heat Transfer; Part A: Applications}},
  title        = {{Effects of deposition locations on film cooling with and without a mist injection}},
  url          = {{http://dx.doi.org/10.1080/10407782.2016.1230395}},
  doi          = {{10.1080/10407782.2016.1230395}},
  volume       = {{70}},
  year         = {{2016}},
}