Validity and reliability of an iPad with a three-dimensional camera for posture imaging

Agustsson, A. ; Gislason, M. K. ; Ingvarsson, P. ; Rodby-Bousquet, E. LU and Sveinsson, Th (2019) In Gait and Posture 68. p.357-362
Abstract

Background: It is important to quantify a static posture to evaluate the need for and effectiveness of interventions such as physical management, physiotherapy, spinal orthosis or surgical treatment on the alignment of body segments. Motion analysis systems can be used for this purpose, but they are expensive, require a high degree of technical experience and are not easily accessible. A simpler method is needed to quantify static posture. Research objective: Assess validity and inter and intra rater reliability using an iPad with a 3-D camera to evaluate posture and postural deformity. Method: A 3-D model of a lying posture, created using an iPad with a 3-D camera, was compared to a Qualisys motion analysis system of the same lying... (More)

Background: It is important to quantify a static posture to evaluate the need for and effectiveness of interventions such as physical management, physiotherapy, spinal orthosis or surgical treatment on the alignment of body segments. Motion analysis systems can be used for this purpose, but they are expensive, require a high degree of technical experience and are not easily accessible. A simpler method is needed to quantify static posture. Research objective: Assess validity and inter and intra rater reliability using an iPad with a 3-D camera to evaluate posture and postural deformity. Method: A 3-D model of a lying posture, created using an iPad with a 3-D camera, was compared to a Qualisys motion analysis system of the same lying posture, the latter used as the gold standard. Markers on the trunk and the leg were captured by both systems, and results from distance and angle measurements were compared. Results: All intra-class correlation coefficient values were above 0.98, the highest systematic error was 4.3 mm for length measurements and 0.2° for angle measurements. Significance: A 3-D model of a person, with markers on anatomical landmarks, created with an iPad with a 3-D camera, is a valid and reliable method of quantifying static posture. Conclusion: An iPad with a 3-D camera is a relatively inexpensive, valid and reliable method to quantify static posture in a clinical environment.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Cerebral palsy, Posture, Scoliosis, Surface topography, Windswept hip
in
Gait and Posture
volume
68
pages
6 pages
publisher
Elsevier
external identifiers
  • pmid:30580201
  • scopus:85058691014
ISSN
0966-6362
DOI
10.1016/j.gaitpost.2018.12.018
language
English
LU publication?
yes
id
daca8727-c762-4100-ae15-3346962d80a5
date added to LUP
2019-01-02 12:56:02
date last changed
2024-04-15 19:45:10
@article{daca8727-c762-4100-ae15-3346962d80a5,
  abstract     = {{<p>Background: It is important to quantify a static posture to evaluate the need for and effectiveness of interventions such as physical management, physiotherapy, spinal orthosis or surgical treatment on the alignment of body segments. Motion analysis systems can be used for this purpose, but they are expensive, require a high degree of technical experience and are not easily accessible. A simpler method is needed to quantify static posture. Research objective: Assess validity and inter and intra rater reliability using an iPad with a 3-D camera to evaluate posture and postural deformity. Method: A 3-D model of a lying posture, created using an iPad with a 3-D camera, was compared to a Qualisys motion analysis system of the same lying posture, the latter used as the gold standard. Markers on the trunk and the leg were captured by both systems, and results from distance and angle measurements were compared. Results: All intra-class correlation coefficient values were above 0.98, the highest systematic error was 4.3 mm for length measurements and 0.2° for angle measurements. Significance: A 3-D model of a person, with markers on anatomical landmarks, created with an iPad with a 3-D camera, is a valid and reliable method of quantifying static posture. Conclusion: An iPad with a 3-D camera is a relatively inexpensive, valid and reliable method to quantify static posture in a clinical environment.</p>}},
  author       = {{Agustsson, A. and Gislason, M. K. and Ingvarsson, P. and Rodby-Bousquet, E. and Sveinsson, Th}},
  issn         = {{0966-6362}},
  keywords     = {{Cerebral palsy; Posture; Scoliosis; Surface topography; Windswept hip}},
  language     = {{eng}},
  month        = {{02}},
  pages        = {{357--362}},
  publisher    = {{Elsevier}},
  series       = {{Gait and Posture}},
  title        = {{Validity and reliability of an iPad with a three-dimensional camera for posture imaging}},
  url          = {{http://dx.doi.org/10.1016/j.gaitpost.2018.12.018}},
  doi          = {{10.1016/j.gaitpost.2018.12.018}},
  volume       = {{68}},
  year         = {{2019}},
}