Lukkede anaestesisystemer
(1992) In Ugeskrift for Læger 154(50). p.3573-3576- Abstract
- Anaesthesia with closed anaesthetic systems demands knowledge of the physiology of the patients and of how the various anaesthetic gases behave in the organism as only the gases which the patients produces and absorbs are eliminated and replaced. The system is educational as it provides knowledge of the genuine absorption of oxygen and anaesthetic gases. The method is favourable to the environment as only the gases which are used are supplied and it is thus economical in use although investment in monitoring equipment is necessary. In practice, induction and waking of the patient are complicated with this system and it requires an anaesthetist who constantly adjusts the gases in the circuit.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1106523
- author
- Reinstrup, Peter LU ; Slots, P and Jorgensen, B C
- organization
- alternative title
- Closed anesthetic systems
- publishing date
- 1992
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Ugeskrift for Læger
- volume
- 154
- issue
- 50
- pages
- 3573 - 3576
- publisher
- Den Almindelige Danske Lægeforening
- external identifiers
-
- pmid:1471274
- scopus:0027114653
- ISSN
- 0041-5782
- language
- Danish
- LU publication?
- yes
- id
- 16b367ad-7895-4a90-9860-eb4f8d7dd2fa (old id 1106523)
- date added to LUP
- 2016-04-01 15:46:20
- date last changed
- 2021-01-03 06:14:16
@article{16b367ad-7895-4a90-9860-eb4f8d7dd2fa, abstract = {{Anaesthesia with closed anaesthetic systems demands knowledge of the physiology of the patients and of how the various anaesthetic gases behave in the organism as only the gases which the patients produces and absorbs are eliminated and replaced. The system is educational as it provides knowledge of the genuine absorption of oxygen and anaesthetic gases. The method is favourable to the environment as only the gases which are used are supplied and it is thus economical in use although investment in monitoring equipment is necessary. In practice, induction and waking of the patient are complicated with this system and it requires an anaesthetist who constantly adjusts the gases in the circuit.}}, author = {{Reinstrup, Peter and Slots, P and Jorgensen, B C}}, issn = {{0041-5782}}, language = {{dan}}, number = {{50}}, pages = {{3573--3576}}, publisher = {{Den Almindelige Danske Lægeforening}}, series = {{Ugeskrift for Læger}}, title = {{Lukkede anaestesisystemer}}, volume = {{154}}, year = {{1992}}, }