The effect of endothelin receptor blockade on the development of the Sephadex-induced inflammation in the rat lung
(1996) In Acta Physiologica Scandinavica 158(2). p.189-193- Abstract
- The non-peptide ET-receptor antagonist Bosentan was used to investigate the role of endogenous endothelin-1 (ET-1) in the development of the Sephadex-induced lung inflammation in the rat. Intratracheal instillation of Sephadex caused a 60-fold rise in endothelin-1-like-immunoreactivity (ET-1-LI) in bronchoalveolar lavage fluid (BALF) concomitant with development of lung oedema, an influx of inflammatory cells into the airways and a rise in the protein content in BALF. The ET-1-LI level in lung homogenate was not significantly affected. Pre-treatment with Bosentan reduced ET-1-LI content in the lung parenchyma but increased ET-1-LI levels in BALF, possibly indicating an effective displacement of ET-1 from its receptors. In Bosentan-treated... (More)
- The non-peptide ET-receptor antagonist Bosentan was used to investigate the role of endogenous endothelin-1 (ET-1) in the development of the Sephadex-induced lung inflammation in the rat. Intratracheal instillation of Sephadex caused a 60-fold rise in endothelin-1-like-immunoreactivity (ET-1-LI) in bronchoalveolar lavage fluid (BALF) concomitant with development of lung oedema, an influx of inflammatory cells into the airways and a rise in the protein content in BALF. The ET-1-LI level in lung homogenate was not significantly affected. Pre-treatment with Bosentan reduced ET-1-LI content in the lung parenchyma but increased ET-1-LI levels in BALF, possibly indicating an effective displacement of ET-1 from its receptors. In Bosentan-treated animals there was an enhancement of the lung oedema formation following Sephadex instillation, but no significant change in the number of leucocytes or protein concentration in BALF. The present data thus do not support the hypothesis that endogenous ET-1 mediates oedema formation or leucocyte influx in this model. If anything, Bosentan enhanced the oedema formation in parallel with increased ET-1-LI in BALF. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1111105
- author
- Andersson, Sven LU ; Hemsen, A and Lundberg, J M
- organization
- publishing date
- 1996
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Bronchoalveolar lavage, Bosentan, endothelin, leucocyte recruitment, oedema, rat lung, receptor antagonism, Sephadex
- in
- Acta Physiologica Scandinavica
- volume
- 158
- issue
- 2
- pages
- 189 - 193
- publisher
- Wiley-Blackwell
- external identifiers
-
- pmid:8899066
- scopus:0029819837
- ISSN
- 0001-6772
- DOI
- 10.1046/j.1365-201X.1996.543303000.x
- language
- English
- LU publication?
- yes
- id
- 6b23956a-7b03-4e50-a4c0-6ed38f32edc7 (old id 1111105)
- date added to LUP
- 2016-04-01 16:34:14
- date last changed
- 2024-01-11 10:33:04
@article{6b23956a-7b03-4e50-a4c0-6ed38f32edc7, abstract = {{The non-peptide ET-receptor antagonist Bosentan was used to investigate the role of endogenous endothelin-1 (ET-1) in the development of the Sephadex-induced lung inflammation in the rat. Intratracheal instillation of Sephadex caused a 60-fold rise in endothelin-1-like-immunoreactivity (ET-1-LI) in bronchoalveolar lavage fluid (BALF) concomitant with development of lung oedema, an influx of inflammatory cells into the airways and a rise in the protein content in BALF. The ET-1-LI level in lung homogenate was not significantly affected. Pre-treatment with Bosentan reduced ET-1-LI content in the lung parenchyma but increased ET-1-LI levels in BALF, possibly indicating an effective displacement of ET-1 from its receptors. In Bosentan-treated animals there was an enhancement of the lung oedema formation following Sephadex instillation, but no significant change in the number of leucocytes or protein concentration in BALF. The present data thus do not support the hypothesis that endogenous ET-1 mediates oedema formation or leucocyte influx in this model. If anything, Bosentan enhanced the oedema formation in parallel with increased ET-1-LI in BALF.}}, author = {{Andersson, Sven and Hemsen, A and Lundberg, J M}}, issn = {{0001-6772}}, keywords = {{Bronchoalveolar lavage; Bosentan; endothelin; leucocyte recruitment; oedema; rat lung; receptor antagonism; Sephadex}}, language = {{eng}}, number = {{2}}, pages = {{189--193}}, publisher = {{Wiley-Blackwell}}, series = {{Acta Physiologica Scandinavica}}, title = {{The effect of endothelin receptor blockade on the development of the Sephadex-induced inflammation in the rat lung}}, url = {{http://dx.doi.org/10.1046/j.1365-201X.1996.543303000.x}}, doi = {{10.1046/j.1365-201X.1996.543303000.x}}, volume = {{158}}, year = {{1996}}, }