Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Rupturerat bukaortaaneurysm. Endovaskulär behandling i lokalanestesi

Malina, Martin LU ; Lindblad, Bengt LU ; Sonesson, Björn LU ; Lundell, Anders LU ; Jivegard, Lennart and Ivancev, Krassi LU (2001) In Läkartidningen 98(49). p.5644-5648
Abstract
We report on endovascular repair of a ruptured abdominal aortic aneurysm. A bifurcated stent graft was inserted under local anesthesia. Aortic clamping is rapidly provided by percutaneous placement of an aortic occlusion balloon catheter. Carbon dioxide can usually replace conventional contrast in patients with renal insufficiency. This minimally invasive procedure may reduce perioperative morbidity and mortality in patients with ruptured aortic aneurysms. The advantages and limitations of this novel technique are discussed.
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
alternative title
[Ruptured abdominal aortic aneurysm. Endovascular treatment under local anesthesia]
publishing date
type
Contribution to journal
publication status
published
subject
in
Läkartidningen
volume
98
issue
49
pages
5644 - 5648
publisher
Swedish Medical Association
external identifiers
  • pmid:11783051
  • scopus:0035814567
ISSN
0023-7205
language
Swedish
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Unit for Clinical Vascular Disease Research (013242410), Medical Radiology Unit (013241410), Emergency medicine/Medicine/Surgery (013240200)
id
810ae27a-f087-4e35-9867-f14e1e45f622 (old id 1120054)
alternative location
http://ltarkiv.lakartidningen.se/artNo23882
date added to LUP
2016-04-01 16:38:41
date last changed
2022-04-30 22:45:01
@article{810ae27a-f087-4e35-9867-f14e1e45f622,
  abstract     = {{We report on endovascular repair of a ruptured abdominal aortic aneurysm. A bifurcated stent graft was inserted under local anesthesia. Aortic clamping is rapidly provided by percutaneous placement of an aortic occlusion balloon catheter. Carbon dioxide can usually replace conventional contrast in patients with renal insufficiency. This minimally invasive procedure may reduce perioperative morbidity and mortality in patients with ruptured aortic aneurysms. The advantages and limitations of this novel technique are discussed.}},
  author       = {{Malina, Martin and Lindblad, Bengt and Sonesson, Björn and Lundell, Anders and Jivegard, Lennart and Ivancev, Krassi}},
  issn         = {{0023-7205}},
  language     = {{swe}},
  number       = {{49}},
  pages        = {{5644--5648}},
  publisher    = {{Swedish Medical Association}},
  series       = {{Läkartidningen}},
  title        = {{Rupturerat bukaortaaneurysm. Endovaskulär behandling i lokalanestesi}},
  url          = {{http://ltarkiv.lakartidningen.se/artNo23882}},
  volume       = {{98}},
  year         = {{2001}},
}