Validation of the Swedish short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic floor distress inventory (PFDI-20) and Pelvic organ prolapse/Urinary incontinence sexual questionnaire (PISQ-12).
(2011) In Acta Obstetricia et Gynecologica Scandinavica 90. p.483-487- Abstract
- Objective. To psychometrically evaluate the Swedish translations of the short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic Floor Distress Inventory (PFDI-20) and Pelvic organ prolapse/Urinary incontinence Sexual questionnaire (PISQ-12). Design and setting. University hospital. Sample. Forty-four patients awaiting prolapse surgery. Methods. The dual panel translation method followed by an evaluation of validity and reliability in prolapse patients. Main outcome measures. Construct, convergent and discriminant validity, reliability via test-retest and internal consistency. Results. Item response rates were high (range: 95.5-100%) for PFIQ-7 and PFDI-20. The corrected item-total correlations showed acceptable construct... (More)
- Objective. To psychometrically evaluate the Swedish translations of the short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic Floor Distress Inventory (PFDI-20) and Pelvic organ prolapse/Urinary incontinence Sexual questionnaire (PISQ-12). Design and setting. University hospital. Sample. Forty-four patients awaiting prolapse surgery. Methods. The dual panel translation method followed by an evaluation of validity and reliability in prolapse patients. Main outcome measures. Construct, convergent and discriminant validity, reliability via test-retest and internal consistency. Results. Item response rates were high (range: 95.5-100%) for PFIQ-7 and PFDI-20. The corrected item-total correlations showed acceptable construct validity for PFIQ-7 (r= 0.338-0.826) but low for PFDI-20 (r= 0.116-0.581) and PISQ-12 (r= 0.024-0.735). Acceptable convergent validity was found in all three instruments with a negative correlation with the SF-12. There were no floor- or ceiling effects in the three instruments. In the test-retest analysis intraclass correlation coefficients (ICC) were significant (r= 0.888 - 0.943). Cronbach´s alpha varied between 0.57 and 0.94. Conclusion. This is the first validated translation of the PFIQ-7, PFDI-20 and PISQ-12 in Swedish. All three instruments indicated acceptable psychometric properties. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1832037
- author
- Teleman, Pia LU ; Stenzelius, Karin LU ; Iorizzo, Linda LU and Jakobsson, Ulf LU
- organization
- publishing date
- 2011
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Acta Obstetricia et Gynecologica Scandinavica
- volume
- 90
- pages
- 483 - 487
- publisher
- Wiley-Blackwell
- external identifiers
-
- wos:000290360100011
- pmid:21306343
- scopus:79955058672
- ISSN
- 1600-0412
- DOI
- 10.1111/j.1600-0412.2011.01085.x
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Department of Obstetrics and Gynaecology (Lund) (013018000), Division of Nursing (Closed 2012) (013065000), Family Medicine (013241010)
- id
- 15324921-2f5b-43d3-8c93-8a116800768e (old id 1832037)
- alternative location
- http://www.ncbi.nlm.nih.gov/pubmed/21306343?dopt=Abstract
- date added to LUP
- 2016-04-04 09:16:51
- date last changed
- 2022-01-29 17:06:14
@article{15324921-2f5b-43d3-8c93-8a116800768e, abstract = {{Objective. To psychometrically evaluate the Swedish translations of the short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic Floor Distress Inventory (PFDI-20) and Pelvic organ prolapse/Urinary incontinence Sexual questionnaire (PISQ-12). Design and setting. University hospital. Sample. Forty-four patients awaiting prolapse surgery. Methods. The dual panel translation method followed by an evaluation of validity and reliability in prolapse patients. Main outcome measures. Construct, convergent and discriminant validity, reliability via test-retest and internal consistency. Results. Item response rates were high (range: 95.5-100%) for PFIQ-7 and PFDI-20. The corrected item-total correlations showed acceptable construct validity for PFIQ-7 (r= 0.338-0.826) but low for PFDI-20 (r= 0.116-0.581) and PISQ-12 (r= 0.024-0.735). Acceptable convergent validity was found in all three instruments with a negative correlation with the SF-12. There were no floor- or ceiling effects in the three instruments. In the test-retest analysis intraclass correlation coefficients (ICC) were significant (r= 0.888 - 0.943). Cronbach´s alpha varied between 0.57 and 0.94. Conclusion. This is the first validated translation of the PFIQ-7, PFDI-20 and PISQ-12 in Swedish. All three instruments indicated acceptable psychometric properties.}}, author = {{Teleman, Pia and Stenzelius, Karin and Iorizzo, Linda and Jakobsson, Ulf}}, issn = {{1600-0412}}, language = {{eng}}, pages = {{483--487}}, publisher = {{Wiley-Blackwell}}, series = {{Acta Obstetricia et Gynecologica Scandinavica}}, title = {{Validation of the Swedish short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic floor distress inventory (PFDI-20) and Pelvic organ prolapse/Urinary incontinence sexual questionnaire (PISQ-12).}}, url = {{http://dx.doi.org/10.1111/j.1600-0412.2011.01085.x}}, doi = {{10.1111/j.1600-0412.2011.01085.x}}, volume = {{90}}, year = {{2011}}, }