Development of silicon microstructures and thin-film MALDI target plates for automated proteomics sample identifications
(2001) In Journal of Neuroscience Methods 109(1). p.41-46- Abstract
- Here we report on the development of a proteomic platform utilizing a piezoelectric flow-through dispensing unit made from silicon microstructures. The use of a novel surface coating, where matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI MS) targets were uniformly precoated with a thin film of matrix/nitrocellulose, made the sample preparation straightforward and enabled the enrichment and analysis of proteins at low levels in proteomics samples. We demonstrate this by analyzing excised spots in a biological sample originating from a human fetal fibroblast cell line that was subjected to 2D gel-electrophoresis. Furthermore, a sample deposition rate below 30 Hz results in an increased analyte density on... (More)
- Here we report on the development of a proteomic platform utilizing a piezoelectric flow-through dispensing unit made from silicon microstructures. The use of a novel surface coating, where matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI MS) targets were uniformly precoated with a thin film of matrix/nitrocellulose, made the sample preparation straightforward and enabled the enrichment and analysis of proteins at low levels in proteomics samples. We demonstrate this by analyzing excised spots in a biological sample originating from a human fetal fibroblast cell line that was subjected to 2D gel-electrophoresis. Furthermore, a sample deposition rate below 30 Hz results in an increased analyte density on the dispensed sample spot, rendering signal amplification. In general, the sensitivity for proteins and peptides can be enhanced 10-50 times compared to traditional MALDI sample preparation techniques. (C) 2001 Elsevier Science B.V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/2376410
- author
- Miliotis, T. ; Marko-Varga, György LU ; Nilsson, J. and Laurell, Thomas LU
- organization
- publishing date
- 2001
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- flow-through microdispenser, precoated target plate, MALDI-TOF MS, proteins, ASSISTED-LASER-DESORPTION/IONIZATION, FLIGHT MASS-SPECTROMETRY, PROTEIN, IDENTIFICATION, FUNCTIONAL PROTEOMICS, SIGNAL-TRANSDUCTION, REPRODUCIBILITY, GELS
- in
- Journal of Neuroscience Methods
- volume
- 109
- issue
- 1
- pages
- 41 - 46
- publisher
- Elsevier
- external identifiers
-
- wos:000171197700006
- scopus:0035882298
- ISSN
- 1872-678X
- DOI
- 10.1016/s0165-0270(01)00399-5
- language
- English
- LU publication?
- yes
- additional info
- 1 The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Biomedical Engineering (011200011), Analytical Chemistry (S/LTH) (011001004)
- id
- d048dceb-1194-4757-9586-8ae67be68388 (old id 2376410)
- date added to LUP
- 2016-04-01 12:02:42
- date last changed
- 2025-04-04 14:45:52
@article{d048dceb-1194-4757-9586-8ae67be68388, abstract = {{Here we report on the development of a proteomic platform utilizing a piezoelectric flow-through dispensing unit made from silicon microstructures. The use of a novel surface coating, where matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI MS) targets were uniformly precoated with a thin film of matrix/nitrocellulose, made the sample preparation straightforward and enabled the enrichment and analysis of proteins at low levels in proteomics samples. We demonstrate this by analyzing excised spots in a biological sample originating from a human fetal fibroblast cell line that was subjected to 2D gel-electrophoresis. Furthermore, a sample deposition rate below 30 Hz results in an increased analyte density on the dispensed sample spot, rendering signal amplification. In general, the sensitivity for proteins and peptides can be enhanced 10-50 times compared to traditional MALDI sample preparation techniques. (C) 2001 Elsevier Science B.V. All rights reserved.}}, author = {{Miliotis, T. and Marko-Varga, György and Nilsson, J. and Laurell, Thomas}}, issn = {{1872-678X}}, keywords = {{flow-through microdispenser; precoated target plate; MALDI-TOF MS; proteins; ASSISTED-LASER-DESORPTION/IONIZATION; FLIGHT MASS-SPECTROMETRY; PROTEIN; IDENTIFICATION; FUNCTIONAL PROTEOMICS; SIGNAL-TRANSDUCTION; REPRODUCIBILITY; GELS}}, language = {{eng}}, number = {{1}}, pages = {{41--46}}, publisher = {{Elsevier}}, series = {{Journal of Neuroscience Methods}}, title = {{Development of silicon microstructures and thin-film MALDI target plates for automated proteomics sample identifications}}, url = {{http://dx.doi.org/10.1016/s0165-0270(01)00399-5}}, doi = {{10.1016/s0165-0270(01)00399-5}}, volume = {{109}}, year = {{2001}}, }