Design of concentrating elements with CIS thin-film solar cells for facade integration

Brogren, M ; Wennerberg, J ; Kapper, R and Karlsson, Björn LU (2003) In Solar Energy Materials and Solar Cells 75(3-4). p.567-575
Abstract
A concentrating photovoltaic wall element, including Cu(In, Ga)Se-2-based modules, aluminum reflectors, and an insulation for building integration, has been developed and evaluated. The geometric concentration ratio of the system is about 3 x. However, the measured maximum electric power from the modules is only 1.9 times that of identical vertical modules without reflectors, due to optical losses and a decrease in fill-factor from 0.6 to 0.5 under concentrated light. The optical efficiency of the system is 76% at an effective solar height of 40degrees. (C) 2002 Elsevier Science B.V. All rights reserved.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Cu(In, Ga)Se-2, module design, parabolic concentrators, building integration
in
Solar Energy Materials and Solar Cells
volume
75
issue
3-4
pages
567 - 575
publisher
Elsevier
external identifiers
  • wos:000179679300029
  • scopus:6444245617
ISSN
0927-0248
DOI
10.1016/S0927-0248(02)00162-9
language
English
LU publication?
yes
id
8388048a-da89-4afd-9c09-fa467851418a (old id 321486)
alternative location
http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6V51-45NGMF6-K&_user=745831&_rdoc=1&_fmt=&_orig=search&_sort=d&view=c&_acct=C000041498&_version=1&_urlVersion=0&_userid=745831&md5=a12f2c4a1c983dfb7bca708021ea0287
date added to LUP
2016-04-01 16:07:36
date last changed
2022-01-28 17:28:12
@article{8388048a-da89-4afd-9c09-fa467851418a,
  abstract     = {{A concentrating photovoltaic wall element, including Cu(In, Ga)Se-2-based modules, aluminum reflectors, and an insulation for building integration, has been developed and evaluated. The geometric concentration ratio of the system is about 3 x. However, the measured maximum electric power from the modules is only 1.9 times that of identical vertical modules without reflectors, due to optical losses and a decrease in fill-factor from 0.6 to 0.5 under concentrated light. The optical efficiency of the system is 76% at an effective solar height of 40degrees. (C) 2002 Elsevier Science B.V. All rights reserved.}},
  author       = {{Brogren, M and Wennerberg, J and Kapper, R and Karlsson, Björn}},
  issn         = {{0927-0248}},
  keywords     = {{Cu(In; Ga)Se-2; module design; parabolic concentrators; building integration}},
  language     = {{eng}},
  number       = {{3-4}},
  pages        = {{567--575}},
  publisher    = {{Elsevier}},
  series       = {{Solar Energy Materials and Solar Cells}},
  title        = {{Design of concentrating elements with CIS thin-film solar cells for facade integration}},
  url          = {{http://dx.doi.org/10.1016/S0927-0248(02)00162-9}},
  doi          = {{10.1016/S0927-0248(02)00162-9}},
  volume       = {{75}},
  year         = {{2003}},
}