Characterization of thermal neutron beam monitors
(2017) In Physical Review Accelerators and Beams 20(9).- Abstract
Neutron beam monitors with a wide range of efficiencies, low γ sensitivity, and high time and space resolution are required in neutron beam experiments to continuously diagnose the delivered beam. In this work, commercially available neutron beam monitors have been characterized using the R2D2 beamline at IFE (Norway) and using a Be-based neutron source. For the γ sensitivity measurements different γ sources have been used. The evaluation of the monitors includes, the study of their efficiency, attenuation, scattering, and sensitivity to γ. In this work we report the results of this characterization.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/374aa580-91ce-437f-a2b8-63d6ed8c3e6f
- author
- Issa, F. ; Khaplanov, A. LU ; Hall-Wilton, R. LU ; Llamas, I. ; Riktor, M. Dalseth ; Brattheim, S. R. and Perrey, H. LU
- organization
- publishing date
- 2017-09-26
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Physical Review Accelerators and Beams
- volume
- 20
- issue
- 9
- article number
- 092801
- publisher
- American Physical Society
- external identifiers
-
- wos:000411769800002
- scopus:85030330704
- ISSN
- 2469-9888
- DOI
- 10.1103/PhysRevAccelBeams.20.092801
- language
- English
- LU publication?
- yes
- id
- 374aa580-91ce-437f-a2b8-63d6ed8c3e6f
- date added to LUP
- 2017-10-16 12:59:10
- date last changed
- 2025-01-07 22:53:57
@article{374aa580-91ce-437f-a2b8-63d6ed8c3e6f, abstract = {{<p>Neutron beam monitors with a wide range of efficiencies, low γ sensitivity, and high time and space resolution are required in neutron beam experiments to continuously diagnose the delivered beam. In this work, commercially available neutron beam monitors have been characterized using the R2D2 beamline at IFE (Norway) and using a Be-based neutron source. For the γ sensitivity measurements different γ sources have been used. The evaluation of the monitors includes, the study of their efficiency, attenuation, scattering, and sensitivity to γ. In this work we report the results of this characterization.</p>}}, author = {{Issa, F. and Khaplanov, A. and Hall-Wilton, R. and Llamas, I. and Riktor, M. Dalseth and Brattheim, S. R. and Perrey, H.}}, issn = {{2469-9888}}, language = {{eng}}, month = {{09}}, number = {{9}}, publisher = {{American Physical Society}}, series = {{Physical Review Accelerators and Beams}}, title = {{Characterization of thermal neutron beam monitors}}, url = {{http://dx.doi.org/10.1103/PhysRevAccelBeams.20.092801}}, doi = {{10.1103/PhysRevAccelBeams.20.092801}}, volume = {{20}}, year = {{2017}}, }