Determination of interstitial oxygen concentration in germanium by infrared absorption
(2006) In Applied Physics Reviews 100(3).- Abstract
- The intensities of infrared absorption due to the asymmetric stretching vibrations of interstitial oxygen atoms in Ge crystals enriched with O-16 and O-18 isotopes have been compared with oxygen concentrations determined by means of secondary ion mass spectrometry. For Ge samples with oxygen content less than 5 x 10(17) cm(-3), a good correlation has been found between the values of oxygen concentration and the values of the absorption coefficient at the maximum of the O-16(i) related absorption band at 855.6 cm(-1) with a proportionality coefficient C-O = 1.05 x 10(17) cm(-2). (c) 2006 American Institute of Physics.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/397400
- author
- Litvinov, V. V. ; Svensson, B. G. ; Murin, L. I. ; Lindström, J L LU ; Markevich, V. P. and Peaker, A. R.
- organization
- publishing date
- 2006
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Applied Physics Reviews
- volume
- 100
- issue
- 3
- article number
- 033525
- publisher
- American Institute of Physics (AIP)
- external identifiers
-
- wos:000239764100040
- scopus:33747492295
- ISSN
- 1931-9401
- DOI
- 10.1063/1.2219987
- language
- English
- LU publication?
- yes
- id
- 7cdc655e-77cd-4d37-ab1b-ff8484a4c607 (old id 397400)
- date added to LUP
- 2016-04-01 11:40:02
- date last changed
- 2022-01-26 08:28:02
@article{7cdc655e-77cd-4d37-ab1b-ff8484a4c607, abstract = {{The intensities of infrared absorption due to the asymmetric stretching vibrations of interstitial oxygen atoms in Ge crystals enriched with O-16 and O-18 isotopes have been compared with oxygen concentrations determined by means of secondary ion mass spectrometry. For Ge samples with oxygen content less than 5 x 10(17) cm(-3), a good correlation has been found between the values of oxygen concentration and the values of the absorption coefficient at the maximum of the O-16(i) related absorption band at 855.6 cm(-1) with a proportionality coefficient C-O = 1.05 x 10(17) cm(-2). (c) 2006 American Institute of Physics.}}, author = {{Litvinov, V. V. and Svensson, B. G. and Murin, L. I. and Lindström, J L and Markevich, V. P. and Peaker, A. R.}}, issn = {{1931-9401}}, language = {{eng}}, number = {{3}}, publisher = {{American Institute of Physics (AIP)}}, series = {{Applied Physics Reviews}}, title = {{Determination of interstitial oxygen concentration in germanium by infrared absorption}}, url = {{http://dx.doi.org/10.1063/1.2219987}}, doi = {{10.1063/1.2219987}}, volume = {{100}}, year = {{2006}}, }