A compact microscope setup for multimodal nonlinear imaging in clinics and its application to disease diagnostics
(2013) In Analyst 138(14). p.4048-4057- Abstract
- The past years have seen increasing interest in nonlinear optical microscopic imaging approaches for the investigation of diseases due to the method's unique capabilities of deep tissue penetration, 3D sectioning and molecular contrast. Its application in clinical routine diagnostics, however, is hampered by large and costly equipment requiring trained staff and regular maintenance, hence it has not yet matured to a reliable tool for application in clinics. In this contribution implementing a novel compact fiber laser system into a tailored designed laser scanning microscope results in a small footprint easy to use multimodal imaging platform enabling simultaneously highly efficient generation and acquisition of second harmonic generation... (More)
- The past years have seen increasing interest in nonlinear optical microscopic imaging approaches for the investigation of diseases due to the method's unique capabilities of deep tissue penetration, 3D sectioning and molecular contrast. Its application in clinical routine diagnostics, however, is hampered by large and costly equipment requiring trained staff and regular maintenance, hence it has not yet matured to a reliable tool for application in clinics. In this contribution implementing a novel compact fiber laser system into a tailored designed laser scanning microscope results in a small footprint easy to use multimodal imaging platform enabling simultaneously highly efficient generation and acquisition of second harmonic generation (SHG), two-photon excited fluorescence (TPEF) as well as coherent anti-Stokes Raman scattering (CARS) signals with optimized CARS contrast for lipid imaging for label-free investigation of tissue samples. The instrument combining a laser source and a microscope features a unique combination of the highest NIR transmission and a fourfold enlarged field of view suited for investigating large tissue specimens. Despite its small size and turnkey operation rendering daily alignment dispensable the system provides the highest flexibility, an imaging speed of 1 megapixel per second and diffraction limited spatial resolution. This is illustrated by imaging samples of squamous cell carcinoma of the head and neck (HNSCC) and an animal model of atherosclerosis allowing for a complete characterization of the tissue composition and morphology, i.e. the tissue's morphochemistry. Highly valuable information for clinical diagnostics, e. g. monitoring the disease progression at the cellular level with molecular specificity, can be retrieved. Future combination with microscopic probes for in vivo imaging or even implementation in endoscopes will allow for in vivo grading of HNSCC and characterization of plaque deposits towards the detection of high risk plaques. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/3990507
- author
- organization
- publishing date
- 2013
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Analyst
- volume
- 138
- issue
- 14
- pages
- 4048 - 4057
- publisher
- Royal Society of Chemistry
- external identifiers
-
- wos:000320466200024
- scopus:84891694014
- pmid:23632421
- ISSN
- 1364-5528
- DOI
- 10.1039/c3an00354j
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Chemical Physics (S) (011001060)
- id
- 3207075f-a313-455b-941d-1c19f053361e (old id 3990507)
- date added to LUP
- 2016-04-01 13:04:43
- date last changed
- 2022-02-26 19:12:09
@article{3207075f-a313-455b-941d-1c19f053361e, abstract = {{The past years have seen increasing interest in nonlinear optical microscopic imaging approaches for the investigation of diseases due to the method's unique capabilities of deep tissue penetration, 3D sectioning and molecular contrast. Its application in clinical routine diagnostics, however, is hampered by large and costly equipment requiring trained staff and regular maintenance, hence it has not yet matured to a reliable tool for application in clinics. In this contribution implementing a novel compact fiber laser system into a tailored designed laser scanning microscope results in a small footprint easy to use multimodal imaging platform enabling simultaneously highly efficient generation and acquisition of second harmonic generation (SHG), two-photon excited fluorescence (TPEF) as well as coherent anti-Stokes Raman scattering (CARS) signals with optimized CARS contrast for lipid imaging for label-free investigation of tissue samples. The instrument combining a laser source and a microscope features a unique combination of the highest NIR transmission and a fourfold enlarged field of view suited for investigating large tissue specimens. Despite its small size and turnkey operation rendering daily alignment dispensable the system provides the highest flexibility, an imaging speed of 1 megapixel per second and diffraction limited spatial resolution. This is illustrated by imaging samples of squamous cell carcinoma of the head and neck (HNSCC) and an animal model of atherosclerosis allowing for a complete characterization of the tissue composition and morphology, i.e. the tissue's morphochemistry. Highly valuable information for clinical diagnostics, e. g. monitoring the disease progression at the cellular level with molecular specificity, can be retrieved. Future combination with microscopic probes for in vivo imaging or even implementation in endoscopes will allow for in vivo grading of HNSCC and characterization of plaque deposits towards the detection of high risk plaques.}}, author = {{Meyer, Tobias and Baumgartl, Martin and Gottschall, Thomas and Pascher, Torbjörn and Wuttig, Andreas and Matthaeus, Christian and Romeike, Bernd F. M. and Brehm, Bernhard R. and Limpert, Jens and Tuennermann, Andreas and Guntinas-Lichius, Orlando and Dietzek, Benjamin and Schmitti, Michael and Popp, Juergen}}, issn = {{1364-5528}}, language = {{eng}}, number = {{14}}, pages = {{4048--4057}}, publisher = {{Royal Society of Chemistry}}, series = {{Analyst}}, title = {{A compact microscope setup for multimodal nonlinear imaging in clinics and its application to disease diagnostics}}, url = {{http://dx.doi.org/10.1039/c3an00354j}}, doi = {{10.1039/c3an00354j}}, volume = {{138}}, year = {{2013}}, }