Age-related circulatory responses to whole body cooling: observations by ballistocardiographic EMFi sensors

Alametsä, Jarmo ; Smolander, Juhani LU ; Vanggaard, Leif ; Halder, Amitava LU ; Lundgren Kownacki, Karin LU ; Gao, Chuansi LU ; Viik, Jari and Kuklane, Kalev LU (2014) Ambience14 & 10I3M, Scientific conference for Smart and functional textiles, Well-Being, Thermal comfort in clothing, Design, Thermal Manikins and Modelling In Proceedings of Ambience, Scientific Conference for Smart Textiles 1.
Abstract
The purpose was to study age related changes in circulatory system via Ballistocardiography (BCG) by utilizing Electromechanical Film (EMFi) sensors by gradually changing the ambient temperature from a thermoneutral area to cold direction. ECG and BCG were recorded from a young person (23 years) and from an older person (78 years), both males. During the tests, brachium blood pressure (BP) and pulse signals were recorded from neck and ankle (with EMFi sensor strips). Thermal camera images were taken in order to find out temperature changes in whole body and limbs. Temporal durations and amplitudes of seat BCG:s components (systolic and diastolic) as well as from pulse signals from neck and ankle were calculated. Aortic pulse wave velocity... (More)
The purpose was to study age related changes in circulatory system via Ballistocardiography (BCG) by utilizing Electromechanical Film (EMFi) sensors by gradually changing the ambient temperature from a thermoneutral area to cold direction. ECG and BCG were recorded from a young person (23 years) and from an older person (78 years), both males. During the tests, brachium blood pressure (BP) and pulse signals were recorded from neck and ankle (with EMFi sensor strips). Thermal camera images were taken in order to find out temperature changes in whole body and limbs. Temporal durations and amplitudes of seat BCG:s components (systolic and diastolic) as well as from pulse signals from neck and ankle were calculated. Aortic pulse wave velocity (PWV) was obtained by utilizing the time between ECG’s R wave and maximum value of the ankle pulse signal.

In both persons, the ankle pulse amplitude decreased when propagating to cold direction and increased in young person when returning to warmer ambient temperature. With young and old BCG:s systolic and diastolic temporal complexes remained stable, but systolic amplitudes increased in the older person (AHI 1.02 – 2.87, AIJ 0.7 – 2.66) as well as diastolic amplitudes (old; AKL 0.47 – 2.37). In the older person, PWV increased when moving to colder side. BP increased with a young person (from 95/64 to 132/75 mmHg), and with older person (from 125/68 to 176/101 mmHg) having a prominent rise in diastolic values during the cooling. The neck pulse wave amplitude AOP rise was modest with the younger person and had variation with the older person. Older person had also more intensive shivering compared to younger one. With the older person, the limbs stayed cold in thermal images when returning from cold to thermoneutral area. The present preliminary observations indicated clear age-related differences in the circulatory response to a mild whole-body thermal challenge. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
EMFi, BCG, thermoneutral area, thermal balance
host publication
Proceedings of Ambience 14&10i3m : Scientific Conference for Smart and Functional Textiles, Well-Being, Thermal Comfort in Clothing, Design, Thermal Manikins and Modellin, 7-9 September 2014, Tampere, Finland - Scientific Conference for Smart and Functional Textiles, Well-Being, Thermal Comfort in Clothing, Design, Thermal Manikins and Modellin, 7-9 September 2014, Tampere, Finland
series title
Proceedings of Ambience, Scientific Conference for Smart Textiles
volume
1
pages
6 pages
publisher
Tampere University of Technology
conference name
Ambience14 & 10I3M, Scientific conference for Smart and functional textiles, Well-Being, Thermal comfort in clothing, Design, Thermal Manikins and Modelling
conference location
Tampere Hall, Tampere, Finland
conference dates
2014-09-07 - 2014-09-09
ISSN
2342-4540
ISBN
978-952-15-3269-6
language
English
LU publication?
yes
id
f1d5c984-d4c0-4e43-b01a-c0f7385511b2 (old id 4647057)
date added to LUP
2016-04-04 12:17:17
date last changed
2018-11-21 21:10:05
@inproceedings{f1d5c984-d4c0-4e43-b01a-c0f7385511b2,
  abstract     = {{The purpose was to study age related changes in circulatory system via Ballistocardiography (BCG) by utilizing Electromechanical Film (EMFi) sensors by gradually changing the ambient temperature from a thermoneutral area to cold direction. ECG and BCG were recorded from a young person (23 years) and from an older person (78 years), both males. During the tests, brachium blood pressure (BP) and pulse signals were recorded from neck and ankle (with EMFi sensor strips). Thermal camera images were taken in order to find out temperature changes in whole body and limbs. Temporal durations and amplitudes of seat BCG:s components (systolic and diastolic) as well as from pulse signals from neck and ankle were calculated. Aortic pulse wave velocity (PWV) was obtained by utilizing the time between ECG’s R wave and maximum value of the ankle pulse signal.<br/><br>
In both persons, the ankle pulse amplitude decreased when propagating to cold direction and increased in young person when returning to warmer ambient temperature. With young and old BCG:s systolic and diastolic temporal complexes remained stable, but systolic amplitudes increased in the older person (AHI 1.02 – 2.87, AIJ 0.7 – 2.66) as well as diastolic amplitudes (old; AKL 0.47 – 2.37). In the older person, PWV increased when moving to colder side. BP increased with a young person (from 95/64 to 132/75 mmHg), and with older person (from 125/68 to 176/101 mmHg) having a prominent rise in diastolic values during the cooling. The neck pulse wave amplitude AOP rise was modest with the younger person and had variation with the older person. Older person had also more intensive shivering compared to younger one. With the older person, the limbs stayed cold in thermal images when returning from cold to thermoneutral area. The present preliminary observations indicated clear age-related differences in the circulatory response to a mild whole-body thermal challenge.}},
  author       = {{Alametsä, Jarmo and Smolander, Juhani and Vanggaard, Leif and Halder, Amitava and Lundgren Kownacki, Karin and Gao, Chuansi and Viik, Jari and Kuklane, Kalev}},
  booktitle    = {{Proceedings of Ambience 14&10i3m : Scientific Conference for Smart and Functional Textiles, Well-Being, Thermal Comfort in Clothing, Design, Thermal Manikins and Modellin, 7-9 September 2014, Tampere, Finland}},
  isbn         = {{978-952-15-3269-6}},
  issn         = {{2342-4540}},
  keywords     = {{EMFi; BCG; thermoneutral area; thermal balance}},
  language     = {{eng}},
  publisher    = {{Tampere University of Technology}},
  series       = {{Proceedings of Ambience, Scientific Conference for Smart Textiles}},
  title        = {{Age-related circulatory responses to whole body cooling: observations by ballistocardiographic EMFi sensors}},
  url          = {{https://lup.lub.lu.se/search/files/5970836/4647058.pdf}},
  volume       = {{1}},
  year         = {{2014}},
}