Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison
(2014) In Radiation Measurements 71. p.475-479- Abstract
- In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute... (More)
- In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. (C) 2014 Elsevier Ltd. All rights reserved. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/5084859
- author
- organization
- publishing date
- 2014
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Retrospective dosimetry, Radiological accident, Emergency dosimeter, OSL, Resistor, Mobile phones
- in
- Radiation Measurements
- volume
- 71
- pages
- 475 - 479
- publisher
- Elsevier
- external identifiers
-
- wos:000347494400102
- scopus:84921460124
- ISSN
- 1879-0925
- DOI
- 10.1016/j.radmeas.2014.03.016
- language
- English
- LU publication?
- yes
- id
- 7b381bdc-9cc5-451b-bfc3-32cedd80ab62 (old id 5084859)
- date added to LUP
- 2016-04-01 10:59:28
- date last changed
- 2022-05-13 22:07:39
@article{7b381bdc-9cc5-451b-bfc3-32cedd80ab62, abstract = {{In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. (C) 2014 Elsevier Ltd. All rights reserved.}}, author = {{Bassinet, C. and Woda, C. and Bortolin, E. and Della Monaca, S. and Fattibene, P. and Quattrini, M. C. and Bulanek, B. and Ekendahl, D. and Burbidge, C. I. and Cauwels, V. and Kouroukla, E. and Geber, Therese and Mrozik, A. and Marczewska, B. and Bilski, P. and Sholom, S. and McKeever, S. W. S. and Smith, R. W. and Veronese, I. and Galli, A. and Panzeri, L. and Martini, M.}}, issn = {{1879-0925}}, keywords = {{Retrospective dosimetry; Radiological accident; Emergency dosimeter; OSL; Resistor; Mobile phones}}, language = {{eng}}, pages = {{475--479}}, publisher = {{Elsevier}}, series = {{Radiation Measurements}}, title = {{Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison}}, url = {{http://dx.doi.org/10.1016/j.radmeas.2014.03.016}}, doi = {{10.1016/j.radmeas.2014.03.016}}, volume = {{71}}, year = {{2014}}, }