Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

New non-invasive method for intima-media thickness and intima-media compression measurements

Cinthio, Magnus LU ; Jansson, Tomas LU ; Persson, Hans W LU ; Lindström, Kjell LU and Rydén Ahlgren, Åsa LU orcid (2005) IEEE Ultrasonics Symposium, 2005 1. p.389-392
Abstract
Intim a-media thickness (IMT) is considered as a valuable marker of early atherosclerosis. We suggest a new algorithm for simultaneous measurements of absolute diameter at diastole, distension (diameter change), IMT at diastole and the intima-media compression (IMC) with a new fast, robust, high-resolution, and automatic algorithm utilizing the ultrasonic gray-scale information. The new algorithm is evaluated in a limited in vivo study on the common carotid artery of 5 healthy volunteers. The standard deviation within an investigation was (8 ± 4 μm; range 4-14 μm) during IMC measurements, (8 ± 5 μm; range 4-16 μm) during the measurements of the IMT at diastole, (30 ±36 μm; range 6-92 μm) during the distension measurements and (48 ±49 μm;... (More)
Intim a-media thickness (IMT) is considered as a valuable marker of early atherosclerosis. We suggest a new algorithm for simultaneous measurements of absolute diameter at diastole, distension (diameter change), IMT at diastole and the intima-media compression (IMC) with a new fast, robust, high-resolution, and automatic algorithm utilizing the ultrasonic gray-scale information. The new algorithm is evaluated in a limited in vivo study on the common carotid artery of 5 healthy volunteers. The standard deviation within an investigation was (8 ± 4 μm; range 4-14 μm) during IMC measurements, (8 ± 5 μm; range 4-16 μm) during the measurements of the IMT at diastole, (30 ±36 μm; range 6-92 μm) during the distension measurements and (48 ±49 μm; range 15-134 μm) during the measurements of the lumen diameter at diastole. The evaluation shows that the algorithm is fast and that the reproducibility and resolution are more than sufficient for in vivo studies. © 2005 IEEE. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
Lumen diameter, Common carotid artery, Intima media thickness (IMT), Intima media compression (IMC)
host publication
Proceedings - IEEE Ultrasonics Symposium
volume
1
pages
389 - 392
publisher
IEEE - Institute of Electrical and Electronics Engineers Inc.
conference name
IEEE Ultrasonics Symposium, 2005
conference location
Rotterdam, Netherlands
conference dates
2005-09-18 - 2005-09-21
external identifiers
  • wos:000236090700095
  • scopus:33847109679
ISSN
1051-0117
ISBN
0780393821
DOI
10.1109/ULTSYM.2005.1602875
language
English
LU publication?
yes
id
4dec876e-d1af-4041-a055-eaa2694bb63f (old id 615694)
date added to LUP
2016-04-01 17:01:39
date last changed
2023-09-05 05:49:21
@inproceedings{4dec876e-d1af-4041-a055-eaa2694bb63f,
  abstract     = {{Intim a-media thickness (IMT) is considered as a valuable marker of early atherosclerosis. We suggest a new algorithm for simultaneous measurements of absolute diameter at diastole, distension (diameter change), IMT at diastole and the intima-media compression (IMC) with a new fast, robust, high-resolution, and automatic algorithm utilizing the ultrasonic gray-scale information. The new algorithm is evaluated in a limited in vivo study on the common carotid artery of 5 healthy volunteers. The standard deviation within an investigation was (8 ± 4 μm; range 4-14 μm) during IMC measurements, (8 ± 5 μm; range 4-16 μm) during the measurements of the IMT at diastole, (30 ±36 μm; range 6-92 μm) during the distension measurements and (48 ±49 μm; range 15-134 μm) during the measurements of the lumen diameter at diastole. The evaluation shows that the algorithm is fast and that the reproducibility and resolution are more than sufficient for in vivo studies. © 2005 IEEE.}},
  author       = {{Cinthio, Magnus and Jansson, Tomas and Persson, Hans W and Lindström, Kjell and Rydén Ahlgren, Åsa}},
  booktitle    = {{Proceedings - IEEE Ultrasonics Symposium}},
  isbn         = {{0780393821}},
  issn         = {{1051-0117}},
  keywords     = {{Lumen diameter; Common carotid artery; Intima media thickness (IMT); Intima media compression (IMC)}},
  language     = {{eng}},
  pages        = {{389--392}},
  publisher    = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}},
  title        = {{New non-invasive method for intima-media thickness and intima-media compression measurements}},
  url          = {{http://dx.doi.org/10.1109/ULTSYM.2005.1602875}},
  doi          = {{10.1109/ULTSYM.2005.1602875}},
  volume       = {{1}},
  year         = {{2005}},
}