Improvement of the detection of myocardial ischemia thanks to information technologies

Fayn, Jocelyne ; Rubel, Paul ; Pahlm, Olle LU and Wagner, Galen S. (2007) In International Journal of Cardiology 120(2). p.172-180
Abstract
Background: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. Methods: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary... (More)
Background: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. Methods: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary angioplasty (PTCA) recorded during balloon inflation as an experimental model of ECG changes induced by coronary artery occlusion. The spatiotemporal ECG changes were measured according to the CAVIAR method and assessed by multivariate discriminant analysis in reference to serial changes of control recordings and standard ECG criteria. Results: The diagnostic accuracy of the CAVIAR criteria for ischemia detection was 97%, with sensitivity of 98% and specificity of 96%, whereas the diagnostic accuracy of the conventional ST-segment criteria was 74%, with sensitivity of 60% and specificity of 88%. The increase of overall performance was obtained for all the occlusion locations. Conclusions: Computer-assisted quantitative serial ECG analysis, taking into account the spatiotemporal changes of the QRS and T waves, would provide the physician with additional information for significantly improving the detection of transmural myocardial ischemia. (C) 2006 Elsevier Ireland Ltd. All rights reserved. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
diagnosis, angioplasty, computer-assisted, acute myocardial ischemia, electrocardiography
in
International Journal of Cardiology
volume
120
issue
2
pages
172 - 180
publisher
Elsevier
external identifiers
  • wos:000248799300006
  • scopus:34447251051
ISSN
0167-5273
DOI
10.1016/j.ijcard.2006.09.025
language
English
LU publication?
yes
id
7c057afe-6ad1-4be0-9236-bf05f6767241 (old id 688999)
date added to LUP
2016-04-01 11:54:24
date last changed
2022-01-26 19:59:27
@article{7c057afe-6ad1-4be0-9236-bf05f6767241,
  abstract     = {{Background: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. Methods: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary angioplasty (PTCA) recorded during balloon inflation as an experimental model of ECG changes induced by coronary artery occlusion. The spatiotemporal ECG changes were measured according to the CAVIAR method and assessed by multivariate discriminant analysis in reference to serial changes of control recordings and standard ECG criteria. Results: The diagnostic accuracy of the CAVIAR criteria for ischemia detection was 97%, with sensitivity of 98% and specificity of 96%, whereas the diagnostic accuracy of the conventional ST-segment criteria was 74%, with sensitivity of 60% and specificity of 88%. The increase of overall performance was obtained for all the occlusion locations. Conclusions: Computer-assisted quantitative serial ECG analysis, taking into account the spatiotemporal changes of the QRS and T waves, would provide the physician with additional information for significantly improving the detection of transmural myocardial ischemia. (C) 2006 Elsevier Ireland Ltd. All rights reserved.}},
  author       = {{Fayn, Jocelyne and Rubel, Paul and Pahlm, Olle and Wagner, Galen S.}},
  issn         = {{0167-5273}},
  keywords     = {{diagnosis; angioplasty; computer-assisted; acute myocardial ischemia; electrocardiography}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{172--180}},
  publisher    = {{Elsevier}},
  series       = {{International Journal of Cardiology}},
  title        = {{Improvement of the detection of myocardial ischemia thanks to information technologies}},
  url          = {{http://dx.doi.org/10.1016/j.ijcard.2006.09.025}},
  doi          = {{10.1016/j.ijcard.2006.09.025}},
  volume       = {{120}},
  year         = {{2007}},
}