Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

In vivo high field myelin water imaging: Investigating the T2 distribution at 7T

Wiggermann, Vanessa ; MacKay, Alex L ; Helms, Gunther LU orcid and Rauscher, Alexander (2018) In Proc Intl Soc Magn Reson Med 26.
Abstract
With the increased frequency of human 7T scanners, there is also a drive towards the implementation advanced MR sequences, such a myelin water imaging, at high fields. Here, we demonstrate the feasibility of translating 3T myelin acquisitions scheme, GRASE, to 7T. We studied the distribution of T values at 7T and determined that myelin water has a T <25ms. We obtained excellent agreement for myelin water fraction values in the corpus callosum between 3T and 7T.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
In vivo high field myelin water imaging: Investigating the T2 distribution at 7T
series title
Proc Intl Soc Magn Reson Med
volume
26
article number
5499
pages
3 pages
publisher
International Society for Magnetic Resonance in Medicine
ISSN
1545-4428
project
T2 mapping and myelin water imaging at 7T using 3D GraSe
language
English
LU publication?
yes
id
76516f9a-e94b-4f70-8c51-bd6ce422d735
alternative location
http://indexsmart.mirasmart.com/ISMRM2018/PDFfiles/5499.html
date added to LUP
2018-08-10 21:02:54
date last changed
2022-03-16 13:53:45
@inproceedings{76516f9a-e94b-4f70-8c51-bd6ce422d735,
  abstract     = {{With the increased frequency of human 7T scanners, there is also a drive towards the implementation advanced MR sequences, such a myelin water imaging, at high fields. Here, we demonstrate the feasibility of translating 3T myelin acquisitions scheme, GRASE, to 7T. We studied the distribution of T values at 7T and determined that myelin water has a T &lt;25ms. We obtained excellent agreement for myelin water fraction values in the corpus callosum between 3T and 7T.}},
  author       = {{Wiggermann, Vanessa and MacKay, Alex L and Helms, Gunther and Rauscher, Alexander}},
  booktitle    = {{In vivo high field myelin water imaging: Investigating the T2 distribution at 7T}},
  issn         = {{1545-4428}},
  language     = {{eng}},
  month        = {{06}},
  publisher    = {{International Society for Magnetic Resonance in Medicine}},
  series       = {{Proc Intl Soc Magn Reson Med}},
  title        = {{In vivo high field myelin water imaging: Investigating the T2 distribution at 7T}},
  url          = {{https://lup.lub.lu.se/search/files/49254951/Proc.Intl.Soc.Magn.Reson.Med.26_2018_2655.pdf}},
  volume       = {{26}},
  year         = {{2018}},
}