OPTIMIZATION OF PHOTOEMISSION BLADE X-RAY BEAM POSITION MONITOR FOR WIDE RANGE OF UNDULATOR GAP OPERATION
(2025) 14th International Beam Instrumentation Conference, IBIC 2025 In Proceedings of the International Beam Instrumentation Conference, IBIC p.781-783- Abstract
Optimization of the photoemission blade type XBPM mostly performed to increase its resolution by increasing the readout signal current and by optimizing blades geometry. This requires tailoring of the XBPM for a particular undulator, making almost every XBPM unique at the Synchrotron Radiation facility. In many cases the calibration coefficient is gap dependent. To overcome those drawbacks an alternative optimization strategy is considered which will help to minimize gap dependence and could provide a unified XBPM design for all XBPM at Synchrotron Radiation (SR) facility.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/76ad1af7-23bb-41fd-9e48-85f689639e99
- author
- Ilinski, P. LU
- organization
- publishing date
- 2025
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- Proceedings of the 14th International Beam Instrumentation Conference
- series title
- Proceedings of the International Beam Instrumentation Conference, IBIC
- editor
- Kumar, Narender
- pages
- 3 pages
- publisher
- JACoW Publishing
- conference name
- 14th International Beam Instrumentation Conference, IBIC 2025
- conference location
- Liverpool, United Kingdom
- conference dates
- 2025-09-07 - 2025-09-11
- external identifiers
-
- scopus:105038456670
- ISSN
- 2673-5350
- ISBN
- 9783954502622
- DOI
- 10.18429/JACoW-IBIC2025-WEPMO24
- language
- English
- LU publication?
- yes
- additional info
- Publisher Copyright: © 2025 International Beam Instrumentation Conference.All rights reserved.
- id
- 76ad1af7-23bb-41fd-9e48-85f689639e99
- date added to LUP
- 2026-07-16 14:13:45
- date last changed
- 2026-08-10 08:07:15
@inproceedings{76ad1af7-23bb-41fd-9e48-85f689639e99,
abstract = {{<p>Optimization of the photoemission blade type XBPM mostly performed to increase its resolution by increasing the readout signal current and by optimizing blades geometry. This requires tailoring of the XBPM for a particular undulator, making almost every XBPM unique at the Synchrotron Radiation facility. In many cases the calibration coefficient is gap dependent. To overcome those drawbacks an alternative optimization strategy is considered which will help to minimize gap dependence and could provide a unified XBPM design for all XBPM at Synchrotron Radiation (SR) facility.</p>}},
author = {{Ilinski, P.}},
booktitle = {{Proceedings of the 14th International Beam Instrumentation Conference}},
editor = {{Kumar, Narender}},
isbn = {{9783954502622}},
issn = {{2673-5350}},
language = {{eng}},
pages = {{781--783}},
publisher = {{JACoW Publishing}},
series = {{Proceedings of the International Beam Instrumentation Conference, IBIC}},
title = {{OPTIMIZATION OF PHOTOEMISSION BLADE X-RAY BEAM POSITION MONITOR FOR WIDE RANGE OF UNDULATOR GAP OPERATION}},
url = {{http://dx.doi.org/10.18429/JACoW-IBIC2025-WEPMO24}},
doi = {{10.18429/JACoW-IBIC2025-WEPMO24}},
year = {{2025}},
}