Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Performance studies under high irradiation and ageing properties of resistive bulk Micromegas chambers at the new CERN Gamma Irradiation Facility

Sidiropoulou, O. ; Gonzalez, B. Alvarez ; Bianco, M ; Farina, E. M. ; Iengo, P ; Longo, L. ; Pfeiffer, D. LU and Wotschack, J. (2017) In Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 845. p.293-297
Abstract

Resistive bulk Micromegas chambers, produced at CERN, have been installed at the new CERN Gamma Irradiation Facility (GIF++) in order to study the effects of ageing and to evaluate the detector behaviour under high irradiation. The chambers have an active area of 10×10cm2, strip pitch of 400μm and an amplification gap of 128μm. We present the detector performance as a function of the background rate of up to 20MHz/cm2.

Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Ageing studies, Gamma irradiation facility, Micro-pattern gas detectors, Resisistive bulk Micromegas
in
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
volume
845
pages
293 - 297
publisher
Elsevier
external identifiers
  • scopus:84977572363
ISSN
0168-9002
DOI
10.1016/j.nima.2016.06.062
language
English
LU publication?
yes
id
77634eac-db4f-42a6-9b7a-f598a3836030
date added to LUP
2017-02-09 09:25:29
date last changed
2022-04-24 21:33:33
@article{77634eac-db4f-42a6-9b7a-f598a3836030,
  abstract     = {{<p>Resistive bulk Micromegas chambers, produced at CERN, have been installed at the new CERN Gamma Irradiation Facility (GIF++) in order to study the effects of ageing and to evaluate the detector behaviour under high irradiation. The chambers have an active area of 10×10cm<sup>2</sup>, strip pitch of 400μm and an amplification gap of 128μm. We present the detector performance as a function of the background rate of up to 20MHz/cm<sup>2</sup>.</p>}},
  author       = {{Sidiropoulou, O. and Gonzalez, B. Alvarez and Bianco, M and Farina, E. M. and Iengo, P and Longo, L. and Pfeiffer, D. and Wotschack, J.}},
  issn         = {{0168-9002}},
  keywords     = {{Ageing studies; Gamma irradiation facility; Micro-pattern gas detectors; Resisistive bulk Micromegas}},
  language     = {{eng}},
  pages        = {{293--297}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}},
  title        = {{Performance studies under high irradiation and ageing properties of resistive bulk Micromegas chambers at the new CERN Gamma Irradiation Facility}},
  url          = {{http://dx.doi.org/10.1016/j.nima.2016.06.062}},
  doi          = {{10.1016/j.nima.2016.06.062}},
  volume       = {{845}},
  year         = {{2017}},
}