Multipoint temperature and oxygen-concentration measurements using rotational coherent anti-Stokes Raman spectroscopy

Bood, Joakim LU ; Brackmann, Christian LU ; Bengtsson, Per Erik LU orcid and Aldén, Marcus LU (2000) In Optics Letters 25(20). p.1535-1537
Abstract

A novel technique for coherent anti-Stokes Raman spectroscopy (CARS) measurements in multiple points is presented. With a system of cylindrical lenses, each laser beam is split into several focused beams, yielding separate planar boxcars configurations. Spectrally resolved CARS signals are detected at different heights on the CCD chip. With dual-broadband rotational CARS the setup is demonstrated for quantitative measurements of temperature- and oxygen-concentration profiles. The technique was demonstrated for three points only, but it can be extended to more points by use of special optics; this choice must be based on a sufficient signal-to-noise ratio in all points for the actual measurement condition.

Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Optics Letters
volume
25
issue
20
pages
3 pages
publisher
Optical Society of America
external identifiers
  • scopus:0042730609
ISSN
0146-9592
language
English
LU publication?
yes
id
8068e517-6560-4c2d-ad52-2d57494cd8bd
date added to LUP
2016-06-29 16:49:27
date last changed
2022-04-03 18:44:28
@article{8068e517-6560-4c2d-ad52-2d57494cd8bd,
  abstract     = {{<p>A novel technique for coherent anti-Stokes Raman spectroscopy (CARS) measurements in multiple points is presented. With a system of cylindrical lenses, each laser beam is split into several focused beams, yielding separate planar boxcars configurations. Spectrally resolved CARS signals are detected at different heights on the CCD chip. With dual-broadband rotational CARS the setup is demonstrated for quantitative measurements of temperature- and oxygen-concentration profiles. The technique was demonstrated for three points only, but it can be extended to more points by use of special optics; this choice must be based on a sufficient signal-to-noise ratio in all points for the actual measurement condition.</p>}},
  author       = {{Bood, Joakim and Brackmann, Christian and Bengtsson, Per Erik and Aldén, Marcus}},
  issn         = {{0146-9592}},
  language     = {{eng}},
  month        = {{10}},
  number       = {{20}},
  pages        = {{1535--1537}},
  publisher    = {{Optical Society of America}},
  series       = {{Optics Letters}},
  title        = {{Multipoint temperature and oxygen-concentration measurements using rotational coherent anti-Stokes Raman spectroscopy}},
  volume       = {{25}},
  year         = {{2000}},
}