Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

A hyperelastic fibre-reinforced continuum model of healing tendons with distributed collagen fibre orientations.

Bajuri, M N ; Isaksson, Hanna LU orcid ; Eliasson, Pernilla and Thompson, Mark S (2016) In Biomechanics and Modeling in Mechanobiology
Abstract
The healing process of ruptured tendons is problematic due to scar tissue formation and deteriorated material properties, and in some cases, it may take nearly a year to complete. Mechanical loading has been shown to positively influence tendon healing; however, the mechanisms remain unclear. Computational mechanobiology methods employed extensively to model bone healing have achieved high fidelity. This study aimed to investigate whether an established hyperelastic fibre-reinforced continuum model introduced by Gasser, Ogden and Holzapfel (GOH) can be used to capture the mechanical behaviour of the Achilles tendon under loading during discrete timepoints of the healing process and to assess the model's sensitivity to its microstructural... (More)
The healing process of ruptured tendons is problematic due to scar tissue formation and deteriorated material properties, and in some cases, it may take nearly a year to complete. Mechanical loading has been shown to positively influence tendon healing; however, the mechanisms remain unclear. Computational mechanobiology methods employed extensively to model bone healing have achieved high fidelity. This study aimed to investigate whether an established hyperelastic fibre-reinforced continuum model introduced by Gasser, Ogden and Holzapfel (GOH) can be used to capture the mechanical behaviour of the Achilles tendon under loading during discrete timepoints of the healing process and to assess the model's sensitivity to its microstructural parameters. Curve fitting of the GOH model against experimental tensile testing data of rat Achilles tendons at four timepoints during the tendon repair was used and achieved excellent fits ([Formula: see text]). A parametric sensitivity study using a three-level central composite design, which is a fractional factorial design method, showed that the collagen-fibre-related parameters in the GOH model-[Formula: see text] and [Formula: see text]-had almost equal influence on the fitting. This study demonstrates that the GOH hyperelastic fibre-reinforced model is capable of describing the mechanical behaviour of healing tendons and that further experiments should focus on establishing the structural and material parameters of collagen fibres in the healing tissue. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Biomechanics and Modeling in Mechanobiology
publisher
Springer
external identifiers
  • pmid:26951049
  • scopus:84960083355
  • pmid:26951049
  • wos:000388811700005
ISSN
1617-7940
DOI
10.1007/s10237-016-0774-5
language
English
LU publication?
yes
id
8534d839-0361-4e0f-a5ed-a669538721ec (old id 8853140)
date added to LUP
2016-04-01 10:51:55
date last changed
2023-08-31 13:17:00
@article{8534d839-0361-4e0f-a5ed-a669538721ec,
  abstract     = {{The healing process of ruptured tendons is problematic due to scar tissue formation and deteriorated material properties, and in some cases, it may take nearly a year to complete. Mechanical loading has been shown to positively influence tendon healing; however, the mechanisms remain unclear. Computational mechanobiology methods employed extensively to model bone healing have achieved high fidelity. This study aimed to investigate whether an established hyperelastic fibre-reinforced continuum model introduced by Gasser, Ogden and Holzapfel (GOH) can be used to capture the mechanical behaviour of the Achilles tendon under loading during discrete timepoints of the healing process and to assess the model's sensitivity to its microstructural parameters. Curve fitting of the GOH model against experimental tensile testing data of rat Achilles tendons at four timepoints during the tendon repair was used and achieved excellent fits ([Formula: see text]). A parametric sensitivity study using a three-level central composite design, which is a fractional factorial design method, showed that the collagen-fibre-related parameters in the GOH model-[Formula: see text] and [Formula: see text]-had almost equal influence on the fitting. This study demonstrates that the GOH hyperelastic fibre-reinforced model is capable of describing the mechanical behaviour of healing tendons and that further experiments should focus on establishing the structural and material parameters of collagen fibres in the healing tissue.}},
  author       = {{Bajuri, M N and Isaksson, Hanna and Eliasson, Pernilla and Thompson, Mark S}},
  issn         = {{1617-7940}},
  language     = {{eng}},
  month        = {{03}},
  publisher    = {{Springer}},
  series       = {{Biomechanics and Modeling in Mechanobiology}},
  title        = {{A hyperelastic fibre-reinforced continuum model of healing tendons with distributed collagen fibre orientations.}},
  url          = {{http://dx.doi.org/10.1007/s10237-016-0774-5}},
  doi          = {{10.1007/s10237-016-0774-5}},
  year         = {{2016}},
}