A microcalorimetric vessel for monitoring cytotoxic reactions in the micro-submicrowatt region
(1990) In Journal of Biochemical and Biophysical Methods 20(3). p.217-225- Abstract
A microcalorimetric vessel for monitoring the initial phases of cytotoxic reactions in the micro-submicrowatt region has been designed and tested. The vessel is intended to be used witha multichannel microcalorimetric system from Thermometric, Järfälla, Sweden and can be built up stepwise in a modular way. The different functions of perfusion, stirring and addition of small amounts of soluble immune reactants can be used separately but also in combination. This is accomplished by the use of a vertical stirring mechanism and a reaction vessel of low volume, 200 μl. The simplcity of the vessel permits an identical vessel to be used on the reference side, handled in parallel with the measuring vessel. No gas phase is present.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/9687f886-280b-4e2f-aff5-7438613851d3
- author
- Thorén, Sven A. ; Ankerst, Jaro LU and Olov Sjögren, Hans LU
- organization
- publishing date
- 1990
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Cytotoxic reaction, Micro-submicrowatt region, Microcalorimetric vessel, Perfusion, Stirring
- in
- Journal of Biochemical and Biophysical Methods
- volume
- 20
- issue
- 3
- pages
- 217 - 225
- publisher
- Elsevier
- external identifiers
-
- pmid:2345266
- scopus:0025346997
- ISSN
- 0165-022X
- DOI
- 10.1016/0165-022X(90)90080-V
- language
- English
- LU publication?
- yes
- id
- 9687f886-280b-4e2f-aff5-7438613851d3
- date added to LUP
- 2021-01-07 15:19:14
- date last changed
- 2024-01-03 03:07:19
@article{9687f886-280b-4e2f-aff5-7438613851d3, abstract = {{<p>A microcalorimetric vessel for monitoring the initial phases of cytotoxic reactions in the micro-submicrowatt region has been designed and tested. The vessel is intended to be used witha multichannel microcalorimetric system from Thermometric, Järfälla, Sweden and can be built up stepwise in a modular way. The different functions of perfusion, stirring and addition of small amounts of soluble immune reactants can be used separately but also in combination. This is accomplished by the use of a vertical stirring mechanism and a reaction vessel of low volume, 200 μl. The simplcity of the vessel permits an identical vessel to be used on the reference side, handled in parallel with the measuring vessel. No gas phase is present.</p>}}, author = {{Thorén, Sven A. and Ankerst, Jaro and Olov Sjögren, Hans}}, issn = {{0165-022X}}, keywords = {{Cytotoxic reaction; Micro-submicrowatt region; Microcalorimetric vessel; Perfusion; Stirring}}, language = {{eng}}, number = {{3}}, pages = {{217--225}}, publisher = {{Elsevier}}, series = {{Journal of Biochemical and Biophysical Methods}}, title = {{A microcalorimetric vessel for monitoring cytotoxic reactions in the micro-submicrowatt region}}, url = {{http://dx.doi.org/10.1016/0165-022X(90)90080-V}}, doi = {{10.1016/0165-022X(90)90080-V}}, volume = {{20}}, year = {{1990}}, }