(1988) In European Journal Of Nuclear Medicine 14(1). p.17-20- Abstract
Myocardial 201Tl emission computed tomography was performed on 25 normal subjects and 27 patients with angiographically significant coronary artery disease. A semi-automatic computer program was designed to define the left ventricular myocardial volume in all short axis sections. Within this volume the relative mean myocardial pixel count was calculated. This parameter was found to separate the 2 patient groups with a sensitivity of at least 81% at a specificity of 100%.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/a9c91132-3951-4c71-8160-8bdedcd1d754
- author
- Palmer, John LU ; Pahlm, Olle LU ; White, Thomas and Lyttkens, Kerstin LU
- organization
- publishing date
- 1988-04-01
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Tl, Myocardial emission computed tomography, Myocardial scintigraphy, Quantitative evaluation
- in
- European Journal Of Nuclear Medicine
- volume
- 14
- issue
- 1
- pages
- 4 pages
- publisher
- Springer
- external identifiers
-
- scopus:0023888901
- pmid:3260178
- ISSN
- 0340-6997
- DOI
- 10.1007/BF00252611
- language
- English
- LU publication?
- yes
- id
- a9c91132-3951-4c71-8160-8bdedcd1d754
- date added to LUP
- 2019-05-28 22:23:58
- date last changed
- 2024-01-01 08:14:24
@article{a9c91132-3951-4c71-8160-8bdedcd1d754, abstract = {{<p>Myocardial <sup>201</sup>Tl emission computed tomography was performed on 25 normal subjects and 27 patients with angiographically significant coronary artery disease. A semi-automatic computer program was designed to define the left ventricular myocardial volume in all short axis sections. Within this volume the relative mean myocardial pixel count was calculated. This parameter was found to separate the 2 patient groups with a sensitivity of at least 81% at a specificity of 100%.</p>}}, author = {{Palmer, John and Pahlm, Olle and White, Thomas and Lyttkens, Kerstin}}, issn = {{0340-6997}}, keywords = {{Tl; Myocardial emission computed tomography; Myocardial scintigraphy; Quantitative evaluation}}, language = {{eng}}, month = {{04}}, number = {{1}}, pages = {{17--20}}, publisher = {{Springer}}, series = {{European Journal Of Nuclear Medicine}}, title = {{Quantitative evaluation of tomographic 201-thallium myocardial scintigraphy}}, url = {{http://dx.doi.org/10.1007/BF00252611}}, doi = {{10.1007/BF00252611}}, volume = {{14}}, year = {{1988}}, }