New approach for the determination of the standard patient to be used for the optimization of the medical exposure protection
(2014) In Radiatsionnaya Gygiena 7(4). p.111-116- Abstract
- This study is devoted to the assessment of the relations between the digital chest x-ray screening procedure parameters, different dose quantities (DAP, ESD, Effective dose) for different age and gender patient groups and patient’s anthropometric indicators. We selected the anthropometric indicators with the maximum impact
on patient’s doses. We propose a new approach for the determination of the standard patient to be used for the medical exposure protection optimization using DRLs.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/ab3aaebe-746c-420e-9964-af0f2aa8944d
- author
- Vodovatov, Aleksandr LU ; Kamishanskaya, Irina and Drozdov, Aleksandr
- publishing date
- 2014
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- optimization, standard patient, Diagnostic reference level, Effective dose
- in
- Radiatsionnaya Gygiena
- volume
- 7
- issue
- 4
- pages
- 6 pages
- publisher
- Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
- ISSN
- 1998-426X
- language
- English
- LU publication?
- no
- id
- ab3aaebe-746c-420e-9964-af0f2aa8944d
- alternative location
- http://www.radhyg.ru/jour/article/view/29/41
- date added to LUP
- 2018-01-04 11:59:41
- date last changed
- 2018-11-21 21:37:04
@article{ab3aaebe-746c-420e-9964-af0f2aa8944d, abstract = {{This study is devoted to the assessment of the relations between the digital chest x-ray screening procedure parameters, different dose quantities (DAP, ESD, Effective dose) for different age and gender patient groups and patient’s anthropometric indicators. We selected the anthropometric indicators with the maximum impact<br/>on patient’s doses. We propose a new approach for the determination of the standard patient to be used for the medical exposure protection optimization using DRLs.}}, author = {{Vodovatov, Aleksandr and Kamishanskaya, Irina and Drozdov, Aleksandr}}, issn = {{1998-426X}}, keywords = {{optimization; standard patient; Diagnostic reference level; Effective dose}}, language = {{eng}}, number = {{4}}, pages = {{111--116}}, publisher = {{Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev}}, series = {{Radiatsionnaya Gygiena}}, title = {{New approach for the determination of the standard patient to be used for the optimization of the medical exposure protection}}, url = {{https://lup.lub.lu.se/search/files/36213552/_.pdf}}, volume = {{7}}, year = {{2014}}, }