Validation of the Spanish Catquest-9SF in patients with a monofocal or trifocal intraocular lens

Lundström, Mats LU ; Llovet, Fernando ; Llovet, Andrea ; Martinez del Pozo, Mercedes ; Mompean, Blas ; González, José Vincente and Pesudovs, Konrad (2016) In Journal of Cataract and Refractive Surgery 42(12). p.1791-1796
Abstract

Purpose To validate the Spanish Catquest-9SF and study patient-reported visual function after implantation of a trifocal versus a monofocal intraocular lens (IOL). setting Clinica Baviera, Valencia and Madrid, Spain. Design Prospective case series. Methods The Catquest-9SF was translated from English to Spanish according to a standard procedure. The Spanish version was validated through Rasch analysis. Patients completed the Catquest-9SF before cataract surgery and 3 months after the surgery. The change in patient-reported visual function caused by surgery, the level of achieved visual function, and satisfaction with vision after surgery were assessed for bilaterally implanted trifocal IOLs versus monofocal IOLs. Results The Spanish... (More)

Purpose To validate the Spanish Catquest-9SF and study patient-reported visual function after implantation of a trifocal versus a monofocal intraocular lens (IOL). setting Clinica Baviera, Valencia and Madrid, Spain. Design Prospective case series. Methods The Catquest-9SF was translated from English to Spanish according to a standard procedure. The Spanish version was validated through Rasch analysis. Patients completed the Catquest-9SF before cataract surgery and 3 months after the surgery. The change in patient-reported visual function caused by surgery, the level of achieved visual function, and satisfaction with vision after surgery were assessed for bilaterally implanted trifocal IOLs versus monofocal IOLs. Results The Spanish Catquest-9SF showed very good psychometric properties. Patient-reported achieved visual function was significantly better for those with a trifocal IOL than for those with a monofocal IOL (P < .001). This was also true when the groups were matched for age and ocular comorbidity (P = .006). In multivariate analyses of all cases and matched cases (the same age and no comorbidity), the reported visual function was significantly better with trifocal IOLs than with monofocal IOLs (P = .001 and P = .008, respectively). There was greater improvement after trifocal IOL implantation in the matched cases, although not significant (P = .103). Conclusions Results show the Spanish version of Catquest-9SF is a valid patient questionnaire with good psychometric properties. Patients with a trifocal IOL implanted bilaterally reported better visual function than those with a monofocal IOL implanted bilaterally. The change in visual function after surgery was also greater in patients with a trifocal IOL. Financial Disclosure None of the authors has a financial or proprietary interest in any material or method mentioned.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Cataract and Refractive Surgery
volume
42
issue
12
pages
6 pages
publisher
Elsevier
external identifiers
  • scopus:85006802471
  • pmid:28007111
  • wos:000391518100014
ISSN
0886-3350
DOI
10.1016/j.jcrs.2016.10.011
language
English
LU publication?
yes
id
ab98be76-e197-4512-954c-4ec193089199
date added to LUP
2017-01-11 13:56:43
date last changed
2024-05-31 21:02:37
@article{ab98be76-e197-4512-954c-4ec193089199,
  abstract     = {{<p>Purpose To validate the Spanish Catquest-9SF and study patient-reported visual function after implantation of a trifocal versus a monofocal intraocular lens (IOL). setting Clinica Baviera, Valencia and Madrid, Spain. Design Prospective case series. Methods The Catquest-9SF was translated from English to Spanish according to a standard procedure. The Spanish version was validated through Rasch analysis. Patients completed the Catquest-9SF before cataract surgery and 3 months after the surgery. The change in patient-reported visual function caused by surgery, the level of achieved visual function, and satisfaction with vision after surgery were assessed for bilaterally implanted trifocal IOLs versus monofocal IOLs. Results The Spanish Catquest-9SF showed very good psychometric properties. Patient-reported achieved visual function was significantly better for those with a trifocal IOL than for those with a monofocal IOL (P &lt; .001). This was also true when the groups were matched for age and ocular comorbidity (P = .006). In multivariate analyses of all cases and matched cases (the same age and no comorbidity), the reported visual function was significantly better with trifocal IOLs than with monofocal IOLs (P = .001 and P = .008, respectively). There was greater improvement after trifocal IOL implantation in the matched cases, although not significant (P = .103). Conclusions Results show the Spanish version of Catquest-9SF is a valid patient questionnaire with good psychometric properties. Patients with a trifocal IOL implanted bilaterally reported better visual function than those with a monofocal IOL implanted bilaterally. The change in visual function after surgery was also greater in patients with a trifocal IOL. Financial Disclosure None of the authors has a financial or proprietary interest in any material or method mentioned.</p>}},
  author       = {{Lundström, Mats and Llovet, Fernando and Llovet, Andrea and Martinez del Pozo, Mercedes and Mompean, Blas and González, José Vincente and Pesudovs, Konrad}},
  issn         = {{0886-3350}},
  language     = {{eng}},
  month        = {{12}},
  number       = {{12}},
  pages        = {{1791--1796}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Cataract and Refractive Surgery}},
  title        = {{Validation of the Spanish Catquest-9SF in patients with a monofocal or trifocal intraocular lens}},
  url          = {{http://dx.doi.org/10.1016/j.jcrs.2016.10.011}},
  doi          = {{10.1016/j.jcrs.2016.10.011}},
  volume       = {{42}},
  year         = {{2016}},
}