Experimental optimization of X-ray propagation-based phase contrast imaging geometry

Dierks, Hanna LU and Wallentin, Jesper LU (2020) In Optics Express 28(20). p.29562-29575
Abstract

Propagation-based phase contrast imaging (PB-PCI) with an X-ray lab source is a powerful technique to study low absorption samples, e.g. soft tissue or plastics, on the micrometer scale but is often limited by the low flux and coherence of the source. The setup geometry is essential for the performance since there is a trade-off where a short source distance yields a high contrast-to-noise ratio (CNR) but a low relative fringe contrast. While theoretical optimization strategies based on Fresnel propagation have been reported, there is a need for experimental testing of these models. Here, we systematically investigate this trade-off experimentally using two different setups with high-resolution detectors: a custom-built system with a Cu... (More)

Propagation-based phase contrast imaging (PB-PCI) with an X-ray lab source is a powerful technique to study low absorption samples, e.g. soft tissue or plastics, on the micrometer scale but is often limited by the low flux and coherence of the source. The setup geometry is essential for the performance since there is a trade-off where a short source distance yields a high contrast-to-noise ratio (CNR) but a low relative fringe contrast. While theoretical optimization strategies based on Fresnel propagation have been reported, there is a need for experimental testing of these models. Here, we systematically investigate this trade-off experimentally using two different setups with high-resolution detectors: a custom-built system with a Cu X-ray source and a commercial system (Zeiss Xradia) with a W source. The fringe contrast, CNR and fringe separation for a low-absorption test sample were measured for 130 different combinations of magnification and overall distances. We find that these figures-of-merit are sensitive to the magnification and that an optimum can be found that is independent of the overall source-detector distance. In general, we find that the theoretical models show excellent agreement with the measurements. However, this requires the complicated X-ray spectrum to be considered, in particular for the broadband W source.

(Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Optics Express
volume
28
issue
20
pages
14 pages
publisher
Optical Society of America
external identifiers
  • pmid:33114854
  • scopus:85092239561
ISSN
1094-4087
DOI
10.1364/OE.399819
language
English
LU publication?
yes
id
c490c95f-b6d6-4c8e-b355-760af035c6f9
date added to LUP
2020-10-22 08:45:35
date last changed
2024-04-03 15:40:17
@article{c490c95f-b6d6-4c8e-b355-760af035c6f9,
  abstract     = {{<p>Propagation-based phase contrast imaging (PB-PCI) with an X-ray lab source is a powerful technique to study low absorption samples, e.g. soft tissue or plastics, on the micrometer scale but is often limited by the low flux and coherence of the source. The setup geometry is essential for the performance since there is a trade-off where a short source distance yields a high contrast-to-noise ratio (CNR) but a low relative fringe contrast. While theoretical optimization strategies based on Fresnel propagation have been reported, there is a need for experimental testing of these models. Here, we systematically investigate this trade-off experimentally using two different setups with high-resolution detectors: a custom-built system with a Cu X-ray source and a commercial system (Zeiss Xradia) with a W source. The fringe contrast, CNR and fringe separation for a low-absorption test sample were measured for 130 different combinations of magnification and overall distances. We find that these figures-of-merit are sensitive to the magnification and that an optimum can be found that is independent of the overall source-detector distance. In general, we find that the theoretical models show excellent agreement with the measurements. However, this requires the complicated X-ray spectrum to be considered, in particular for the broadband W source.</p>}},
  author       = {{Dierks, Hanna and Wallentin, Jesper}},
  issn         = {{1094-4087}},
  language     = {{eng}},
  month        = {{09}},
  number       = {{20}},
  pages        = {{29562--29575}},
  publisher    = {{Optical Society of America}},
  series       = {{Optics Express}},
  title        = {{Experimental optimization of X-ray propagation-based phase contrast imaging geometry}},
  url          = {{http://dx.doi.org/10.1364/OE.399819}},
  doi          = {{10.1364/OE.399819}},
  volume       = {{28}},
  year         = {{2020}},
}