Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

X-ray absorption spectroscopy of iron tris (bipyridine) using superconducting microcalorimeters

Ullom, J. N. ; Dowell, M. ; Fowler, J. ; Miaja, L. ; O'Neil, G. ; Silverman, K. ; Swetz, D. ; Sagar, D. M. ; Yoon, Z. and Jimenez, R. , et al. (2014) p.1-2
Abstract
We are developing a tabletop apparatus for time-resolved X-ray absorption spectroscopy. Short X-ray pulses are generated by focusing a pulsed 800 nm laser onto a water jet target. X-rays that pass through a sample of interest are detected using energy-resolving superconducting microcalorimeter detectors. We have successfully observed EXAFS features from iron tris(bipyridine) in a water solution. We discuss details of the microcalorimeter spectra and describe the steps that remain before the intrinsic sub-picosecond sensitivity of the apparatus can be realized.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
2014 Conference on Lasers and Electro-Optics (CLEO) : Laser Science to Photonic Applications - Laser Science to Photonic Applications
pages
2 pages
publisher
IEEE - Institute of Electrical and Electronics Engineers Inc.
external identifiers
  • scopus:85088722948
ISBN
978-1-55752-999-2
DOI
10.1364/CLEO_AT.2014.AW1P.3
language
English
LU publication?
yes
id
ffe8e330-c550-43b3-b818-5e54ed2d1f9b
date added to LUP
2016-04-14 06:07:55
date last changed
2023-09-11 16:14:24
@inproceedings{ffe8e330-c550-43b3-b818-5e54ed2d1f9b,
  abstract     = {{We are developing a tabletop apparatus for time-resolved X-ray absorption spectroscopy. Short X-ray pulses are generated by focusing a pulsed 800 nm laser onto a water jet target. X-rays that pass through a sample of interest are detected using energy-resolving superconducting microcalorimeter detectors. We have successfully observed EXAFS features from iron tris(bipyridine) in a water solution. We discuss details of the microcalorimeter spectra and describe the steps that remain before the intrinsic sub-picosecond sensitivity of the apparatus can be realized.}},
  author       = {{Ullom, J. N. and Dowell, M. and Fowler, J. and Miaja, L. and O'Neil, G. and Silverman, K. and Swetz, D. and Sagar, D. M. and Yoon, Z. and Jimenez, R. and Uhlig, J. and Fullagar, W. and Kurunthu, D. and Mandal, U. and Sundstrom, V.}},
  booktitle    = {{2014 Conference on Lasers and Electro-Optics (CLEO) : Laser Science to Photonic Applications}},
  isbn         = {{978-1-55752-999-2}},
  language     = {{eng}},
  pages        = {{1--2}},
  publisher    = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}},
  title        = {{X-ray absorption spectroscopy of iron tris (bipyridine) using superconducting microcalorimeters}},
  url          = {{http://dx.doi.org/10.1364/CLEO_AT.2014.AW1P.3}},
  doi          = {{10.1364/CLEO_AT.2014.AW1P.3}},
  year         = {{2014}},
}