Highly efficient single cell arraying by integrating acoustophoretic cell pre-concentration and deialctrophoretic cell trapping
(2015) In Lab on a Chip 15(22). p.4356-4363- Abstract
- To array rare cells at the single-cell level, the volumetric throughput may become a bottleneck in the cell trapping and the subsequent single-cell analysis, since the target cells per definition commonly exist in a large sample volume after purification from the original sample. Here, we present a novel approach for high throughput single cell arraying by integrating two original microfluidic devices: an acoustofluidic chip and an electroactive microwell array. The velocity of the cells is geared down in the acoustofluidic chip while maintaining a high volume flow rate at the inlet of the microsystem, and the cells are subsequently trapped one by one into the microwell array using dielectrophoresis. The integrated system exhibited a 10... (More)
- To array rare cells at the single-cell level, the volumetric throughput may become a bottleneck in the cell trapping and the subsequent single-cell analysis, since the target cells per definition commonly exist in a large sample volume after purification from the original sample. Here, we present a novel approach for high throughput single cell arraying by integrating two original microfluidic devices: an acoustofluidic chip and an electroactive microwell array. The velocity of the cells is geared down in the acoustofluidic chip while maintaining a high volume flow rate at the inlet of the microsystem, and the cells are subsequently trapped one by one into the microwell array using dielectrophoresis. The integrated system exhibited a 10 times improved sample throughput compared to trapping with the electroactive microwell array chip alone, while maintaining a highly efficient cell recovery above 90%. The results indicate that the serial integration of the acoustophoretic pre-concentration with the dielectrophoretic cell trapping drastically improves the performance of the electroactive microwell array for highly efficient single cell analysis. This simple and effective system for high throughput single cell arraying with further possible integration of additional functions, including cell sorting and downstream analysis after cell trapping, has potential for development to a highly integrated and automated platform for single-cell analysis of rare cells. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/8055530
- author
- Kim, Soo Hyeon ; Antfolk, Maria LU ; Kobayashi, Marina ; Kaneda, Shohei ; Laurell, Thomas LU and Fujii, Teruo
- organization
- publishing date
- 2015
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Lab on a Chip
- volume
- 15
- issue
- 22
- pages
- 4356 - 4363
- publisher
- Royal Society of Chemistry
- external identifiers
-
- pmid:26439940
- wos:000364072300013
- scopus:84946029894
- ISSN
- 1473-0189
- DOI
- 10.1039/C5LC01065A
- language
- English
- LU publication?
- yes
- id
- 0d6860e9-edc3-4c51-8236-68e2b665a6bb (old id 8055530)
- date added to LUP
- 2016-04-01 11:11:46
- date last changed
- 2022-05-13 23:48:02
@article{0d6860e9-edc3-4c51-8236-68e2b665a6bb, abstract = {{To array rare cells at the single-cell level, the volumetric throughput may become a bottleneck in the cell trapping and the subsequent single-cell analysis, since the target cells per definition commonly exist in a large sample volume after purification from the original sample. Here, we present a novel approach for high throughput single cell arraying by integrating two original microfluidic devices: an acoustofluidic chip and an electroactive microwell array. The velocity of the cells is geared down in the acoustofluidic chip while maintaining a high volume flow rate at the inlet of the microsystem, and the cells are subsequently trapped one by one into the microwell array using dielectrophoresis. The integrated system exhibited a 10 times improved sample throughput compared to trapping with the electroactive microwell array chip alone, while maintaining a highly efficient cell recovery above 90%. The results indicate that the serial integration of the acoustophoretic pre-concentration with the dielectrophoretic cell trapping drastically improves the performance of the electroactive microwell array for highly efficient single cell analysis. This simple and effective system for high throughput single cell arraying with further possible integration of additional functions, including cell sorting and downstream analysis after cell trapping, has potential for development to a highly integrated and automated platform for single-cell analysis of rare cells.}}, author = {{Kim, Soo Hyeon and Antfolk, Maria and Kobayashi, Marina and Kaneda, Shohei and Laurell, Thomas and Fujii, Teruo}}, issn = {{1473-0189}}, language = {{eng}}, number = {{22}}, pages = {{4356--4363}}, publisher = {{Royal Society of Chemistry}}, series = {{Lab on a Chip}}, title = {{Highly efficient single cell arraying by integrating acoustophoretic cell pre-concentration and deialctrophoretic cell trapping}}, url = {{http://dx.doi.org/10.1039/C5LC01065A}}, doi = {{10.1039/C5LC01065A}}, volume = {{15}}, year = {{2015}}, }