Comparison of measured and calculated absorbed doses from tangential irradiation of the breast
(1986) In Radiotherapy and Oncology 7(1). p.81-88- Abstract
- Calculated absorbed dose distributions from tangential irradiation of the breast have been compared with TLD measurements in a anthropomorfic body-shaped phantom which has gone through all phases of the radiation treatment planning cycle, including mapping of electron densities with a CT scanner, simulation of beam set-up and several treatments with an accelerator. The absorbed doses, measured in the breast are 2-6% lower than those calculated with the clinically used treatment planning system. The deviation is slightly higher when wedges are used. The main source for this deviation is shown to be the limitations in the loss-of-scatter correction in the dose calculation algorithm used. It has also been noted that the variation of the... (More)
- Calculated absorbed dose distributions from tangential irradiation of the breast have been compared with TLD measurements in a anthropomorfic body-shaped phantom which has gone through all phases of the radiation treatment planning cycle, including mapping of electron densities with a CT scanner, simulation of beam set-up and several treatments with an accelerator. The absorbed doses, measured in the breast are 2-6% lower than those calculated with the clinically used treatment planning system. The deviation is slightly higher when wedges are used. The main source for this deviation is shown to be the limitations in the loss-of-scatter correction in the dose calculation algorithm used. It has also been noted that the variation of the absorbed dose in the target volume is in general smaller than predicted by the calculations. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1103719
- author
- Knöös, Tommy LU ; Ahlgren, Lars and Nilsson, Mats LU
- organization
- publishing date
- 1986
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Tangential treatment, Breast cancer, Radiation therapy, Dose planning, Phantom measurements
- in
- Radiotherapy and Oncology
- volume
- 7
- issue
- 1
- pages
- 81 - 88
- publisher
- Elsevier
- external identifiers
-
- scopus:0022974147
- ISSN
- 1879-0887
- DOI
- 10.1016/S0167-8140(86)80127-X
- language
- English
- LU publication?
- yes
- id
- 6823ce29-9329-4fce-b87b-9d12bc7dab96 (old id 1103719)
- date added to LUP
- 2016-04-01 12:16:51
- date last changed
- 2021-01-03 09:33:55
@article{6823ce29-9329-4fce-b87b-9d12bc7dab96, abstract = {{Calculated absorbed dose distributions from tangential irradiation of the breast have been compared with TLD measurements in a anthropomorfic body-shaped phantom which has gone through all phases of the radiation treatment planning cycle, including mapping of electron densities with a CT scanner, simulation of beam set-up and several treatments with an accelerator. The absorbed doses, measured in the breast are 2-6% lower than those calculated with the clinically used treatment planning system. The deviation is slightly higher when wedges are used. The main source for this deviation is shown to be the limitations in the loss-of-scatter correction in the dose calculation algorithm used. It has also been noted that the variation of the absorbed dose in the target volume is in general smaller than predicted by the calculations.}}, author = {{Knöös, Tommy and Ahlgren, Lars and Nilsson, Mats}}, issn = {{1879-0887}}, keywords = {{Tangential treatment; Breast cancer; Radiation therapy; Dose planning; Phantom measurements}}, language = {{eng}}, number = {{1}}, pages = {{81--88}}, publisher = {{Elsevier}}, series = {{Radiotherapy and Oncology}}, title = {{Comparison of measured and calculated absorbed doses from tangential irradiation of the breast}}, url = {{http://dx.doi.org/10.1016/S0167-8140(86)80127-X}}, doi = {{10.1016/S0167-8140(86)80127-X}}, volume = {{7}}, year = {{1986}}, }