Steroid hormone determination in water using an environmentally friendly membrane based extraction technique.
(2008) In Journal of Chromatography A 1192(1). p.1-8- Abstract
- In this study, a method was developed for determination of steroid hormones (17beta-estradiol, estrone, 17alpha-ethynylestradiol) in tap and sewage water samples from Sweden. Sample preparation and analysis were performed by a hollow-fibre microporous membrane liquid-liquid extraction (HF-MMLLE) set-up combined with gas chromatography-mass spectrometry (GC-MS). In this approach, only the organic liquid in the lumen (10muL) of the hollow-fibre membrane was utilised for depleting extraction. Several parameters were studied, including: type of organic solvent, sample pH, salt and humic acid content. The optimised method allowed the determination of the analyte at the low ngL(-1) level in tap and sewage water. A linear plot gave correlation... (More)
- In this study, a method was developed for determination of steroid hormones (17beta-estradiol, estrone, 17alpha-ethynylestradiol) in tap and sewage water samples from Sweden. Sample preparation and analysis were performed by a hollow-fibre microporous membrane liquid-liquid extraction (HF-MMLLE) set-up combined with gas chromatography-mass spectrometry (GC-MS). In this approach, only the organic liquid in the lumen (10muL) of the hollow-fibre membrane was utilised for depleting extraction. Several parameters were studied, including: type of organic solvent, sample pH, salt and humic acid content. The optimised method allowed the determination of the analyte at the low ngL(-1) level in tap and sewage water. A linear plot gave correlation coefficients better than 0.995 and resulted in a method limit of detection of 1.6, 3 and 10ngL(-1) for 17beta-estradiol, estrone, and 17alpha-ethynylestradiol, respectively, in sewage water. Enrichment factors were over 1400 after derivatisation. The repeatabilities at 50 and 600ngL(-1) were better than 10% and 6%, respectively. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1147657
- author
- Zorita, Saioa LU ; Hallgren, Pär LU and Mathiasson, Lennart LU
- organization
- publishing date
- 2008
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Journal of Chromatography A
- volume
- 1192
- issue
- 1
- pages
- 1 - 8
- publisher
- Elsevier
- external identifiers
-
- wos:000256200700001
- pmid:18394632
- scopus:42649129327
- pmid:18394632
- ISSN
- 0021-9673
- DOI
- 10.1016/j.chroma.2008.03.030
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
- id
- 5ed0f8f8-f95a-4afe-8c42-0a1e94a97315 (old id 1147657)
- date added to LUP
- 2016-04-01 13:36:22
- date last changed
- 2022-01-27 20:04:10
@article{5ed0f8f8-f95a-4afe-8c42-0a1e94a97315, abstract = {{In this study, a method was developed for determination of steroid hormones (17beta-estradiol, estrone, 17alpha-ethynylestradiol) in tap and sewage water samples from Sweden. Sample preparation and analysis were performed by a hollow-fibre microporous membrane liquid-liquid extraction (HF-MMLLE) set-up combined with gas chromatography-mass spectrometry (GC-MS). In this approach, only the organic liquid in the lumen (10muL) of the hollow-fibre membrane was utilised for depleting extraction. Several parameters were studied, including: type of organic solvent, sample pH, salt and humic acid content. The optimised method allowed the determination of the analyte at the low ngL(-1) level in tap and sewage water. A linear plot gave correlation coefficients better than 0.995 and resulted in a method limit of detection of 1.6, 3 and 10ngL(-1) for 17beta-estradiol, estrone, and 17alpha-ethynylestradiol, respectively, in sewage water. Enrichment factors were over 1400 after derivatisation. The repeatabilities at 50 and 600ngL(-1) were better than 10% and 6%, respectively.}}, author = {{Zorita, Saioa and Hallgren, Pär and Mathiasson, Lennart}}, issn = {{0021-9673}}, language = {{eng}}, number = {{1}}, pages = {{1--8}}, publisher = {{Elsevier}}, series = {{Journal of Chromatography A}}, title = {{Steroid hormone determination in water using an environmentally friendly membrane based extraction technique.}}, url = {{http://dx.doi.org/10.1016/j.chroma.2008.03.030}}, doi = {{10.1016/j.chroma.2008.03.030}}, volume = {{1192}}, year = {{2008}}, }