Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases (CLEC(R)).
(2001) In Talanta 54(5). p.963-974- Abstract
- Glucose biosensors based on lyophilised, crystalline and cross-linked glucose oxidase (GOx, CLEC(R)) and commercially available lyophilised GOx immobilised on top of glassy carbon electrodes modified with electrodeposited Prussian Blue are critically compared. Two procedures were carried out for preparing the biosensors: (1) deposition of one layer of adsorbed GOx dissolved in an aqueous solution followed by deposition of two layers of low molecular weight Nafion(R) dissolved in 90% ethanol, and (2) deposition of two layers of a mixture of GOx with Nafion dissolved in 90% ethanol. The performance of the biosensors was evaluated in terms of linear response range for hydrogen peroxide and glucose, detection limit, and susceptibility to some... (More)
- Glucose biosensors based on lyophilised, crystalline and cross-linked glucose oxidase (GOx, CLEC(R)) and commercially available lyophilised GOx immobilised on top of glassy carbon electrodes modified with electrodeposited Prussian Blue are critically compared. Two procedures were carried out for preparing the biosensors: (1) deposition of one layer of adsorbed GOx dissolved in an aqueous solution followed by deposition of two layers of low molecular weight Nafion(R) dissolved in 90% ethanol, and (2) deposition of two layers of a mixture of GOx with Nafion dissolved in 90% ethanol. The performance of the biosensors was evaluated in terms of linear response range for hydrogen peroxide and glucose, detection limit, and susceptibility to some common interfering species (ascorbic acid, acetaminophen and uric acid). The operational stability of the biosensors was evaluated by applying a steady potential of -50 mV versus Ag/AgCl to the glucose biosensor and injecting standard solutions of hydrogen peroxide and glucose (50 muM and 1.0 mM, respectively, in phosphate buffer) for at least 5 h in a flow-injection system. Scanning electron microscopy was used for visualisation of the Prussian Blue redox catalyst and in the presence of the different GOx preparations on the electrode surface. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1261747
- author
- de Mattos, I L ; Lukachova, L V ; Gorton, Lo LU ; Laurell, Thomas LU and Karyakin, A A
- organization
- publishing date
- 2001
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Talanta
- volume
- 54
- issue
- 5
- pages
- 963 - 974
- publisher
- Elsevier
- external identifiers
-
- pmid:18968320
- wos:000169852200020
- scopus:0035927844
- ISSN
- 1873-3573
- DOI
- 10.1016/S0039-9140(01)00367-8
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004), Biomedical Engineering (011200011)
- id
- eab5f474-5eb9-4b2a-9eef-715fa00e9332 (old id 1261747)
- date added to LUP
- 2016-04-01 16:38:25
- date last changed
- 2022-01-28 21:06:45
@article{eab5f474-5eb9-4b2a-9eef-715fa00e9332, abstract = {{Glucose biosensors based on lyophilised, crystalline and cross-linked glucose oxidase (GOx, CLEC(R)) and commercially available lyophilised GOx immobilised on top of glassy carbon electrodes modified with electrodeposited Prussian Blue are critically compared. Two procedures were carried out for preparing the biosensors: (1) deposition of one layer of adsorbed GOx dissolved in an aqueous solution followed by deposition of two layers of low molecular weight Nafion(R) dissolved in 90% ethanol, and (2) deposition of two layers of a mixture of GOx with Nafion dissolved in 90% ethanol. The performance of the biosensors was evaluated in terms of linear response range for hydrogen peroxide and glucose, detection limit, and susceptibility to some common interfering species (ascorbic acid, acetaminophen and uric acid). The operational stability of the biosensors was evaluated by applying a steady potential of -50 mV versus Ag/AgCl to the glucose biosensor and injecting standard solutions of hydrogen peroxide and glucose (50 muM and 1.0 mM, respectively, in phosphate buffer) for at least 5 h in a flow-injection system. Scanning electron microscopy was used for visualisation of the Prussian Blue redox catalyst and in the presence of the different GOx preparations on the electrode surface.}}, author = {{de Mattos, I L and Lukachova, L V and Gorton, Lo and Laurell, Thomas and Karyakin, A A}}, issn = {{1873-3573}}, language = {{eng}}, number = {{5}}, pages = {{963--974}}, publisher = {{Elsevier}}, series = {{Talanta}}, title = {{Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases (CLEC(R)).}}, url = {{http://dx.doi.org/10.1016/S0039-9140(01)00367-8}}, doi = {{10.1016/S0039-9140(01)00367-8}}, volume = {{54}}, year = {{2001}}, }