Performance of the AGATA Gamma-ray Spectrometer in the PreSPEC Set-up at GSI
(2016) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 806. p.258-266- Abstract
- In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the γ-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the γ ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC–AGATA experimental campaign at the GSI... (More)
- In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the γ-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the γ ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC–AGATA experimental campaign at the GSI Helmholtzzentrum für Schwerionenforschung. Using the radioactive sources 56Co, 60Co and 152Eu, absolute and normalized efficiencies and the peak-to-total of the array were measured. These quantities are discussed using different data analysis procedures. The quality of the pulse-shape analysis and the tracking algorithm are evaluated. The agreement between the experimental data and the Geant4 simulations is also investigated (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/8169362
- author
- organization
- publishing date
- 2016
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- gamma-ray spectroscopy, AGATA spectrometer, PreSPEC-AGATA
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 806
- pages
- 9 pages
- publisher
- Elsevier
- external identifiers
-
- wos:000364856100035
- scopus:84945260605
- ISSN
- 0167-5087
- DOI
- 10.1016/j.nima.2015.10.032
- project
- Nuclear Structure at the Limits: Isotope-selective Spectroscopy
- Nuclear Structure Studies near 208Pb and gamma-ray Imaging Techniques
- language
- English
- LU publication?
- yes
- id
- 14b8342e-5543-40cb-baa0-be4a84ef3763 (old id 8169362)
- alternative location
- http://www.sciencedirect.com/science/article/pii/S0168900215012395
- date added to LUP
- 2016-04-01 13:27:04
- date last changed
- 2023-03-27 21:53:14
@article{14b8342e-5543-40cb-baa0-be4a84ef3763, abstract = {{In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the γ-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the γ ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC–AGATA experimental campaign at the GSI Helmholtzzentrum für Schwerionenforschung. Using the radioactive sources 56Co, 60Co and 152Eu, absolute and normalized efficiencies and the peak-to-total of the array were measured. These quantities are discussed using different data analysis procedures. The quality of the pulse-shape analysis and the tracking algorithm are evaluated. The agreement between the experimental data and the Geant4 simulations is also investigated}}, author = {{Lalovic, Natasa and Louchart, C. and Michelagnoli, C. and Perez-Vidal, R.M. and Ralet, D. and Gerl, J. and Rudolph, Dirk and Arici, T. and Bazzacco, D. and Clement, E. and Gadea, A. and Kojouharov, I. and Korichi, A. and Labiche, M. and Ljungvall, J. and Lopez-Martens, A. and Nyberg, J. and Pietralla, N. and Pietri, S. and Stezowski, O. and Collaboration, the AGATA and Collaboration, the PreSPEC}}, issn = {{0167-5087}}, keywords = {{gamma-ray spectroscopy; AGATA spectrometer; PreSPEC-AGATA}}, language = {{eng}}, pages = {{258--266}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{Performance of the AGATA Gamma-ray Spectrometer in the PreSPEC Set-up at GSI}}, url = {{https://lup.lub.lu.se/search/files/3376337/8169364.pdf}}, doi = {{10.1016/j.nima.2015.10.032}}, volume = {{806}}, year = {{2016}}, }